Civic Data
FDA RecallsAbout

FDA Recalls

  • Food recalls
  • Drug recalls
  • Device recalls

Browse

  • All recalls

About

  • About us
  • Guides
  • Data sources
  • Privacy policy

Data

  • OpenFDA API

© 2026Civic Data · Data sourced from OpenFDA, updated weekly · Not affiliated with the U.S. Food and Drug Administration · Always verify against official FDA sources before acting

  1. FDA Recalls
  2. ›Device Recalls

FDA Device Recalls

Recalls of medical devices, diagnostic equipment, implants, and surgical instruments.

Classification
AllClass IClass IIClass III
Status
AllOngoingCompletedTerminated
Date
All timePast 30 daysPast 12 months

Showing 1–8 of 8 recalls for “E. coli”

Class IIOngoing

BD Phoenix M50 instrument -Intended for the rapid identification (ID) and antimicrobial susceptibility testing (AST) of clinically significant bacteria. The BD Phoenix System provides rapid results for most aerobic and facultative anaerobic Grampositive bacteria. Catalog Number: 443624

Becton Dickinson & Co.

Escherichia coli (E. coli) misidentification for clinical samples that were tested on BD Phoenix" M50 instrument and BD Phoenix" 100, may lead to misdiagnosis and inappropriate treatment of infections caused by E. coli,

August 1, 2024 · DeviceView details →
Class IIOngoing

BD Phoenix 100-Intended for the rapid identification (ID) and antimicrobial susceptibility testing (AST) of clinically significant bacteria. The BD Phoenix System provides rapid results for most aerobic and facultative anaerobic Grampositive bacteria. Catalog Number: 448100

Becton Dickinson & Co.

Escherichia coli (E. coli) misidentification for clinical samples that were tested on BD Phoenix" M50 instrument and BD Phoenix" 100, may lead to misdiagnosis and inappropriate treatment of infections caused by E. coli,

August 1, 2024 · DeviceView details →
Class IITerminated

KWIK-STIK(TM), Streptococcus pneumoniae derived from ATCC(R) 49619(TM), packaged as follows: a. KWIK-STIK(TM) 2 Pack; b. KWIK-STIK(TM) 6 Pack. Each KWIK-STIK unit contains a lyophilized microorganism pellet, an ampoule of hydrating fluid, and an inoculating swab. Each device is sealed within a laminated pouch that contains a desiccant to prevent adverse moisture accumulation. KWIK-STIK microorganisms are 3 passages or fewer from the reference culture and are guaranteed to recover when processed using the recommended media and incubation requirements. Available in packs of 2 or 6.

Microbiologics Inc

Potential contamination with S. epidermidis E. coli and S. warneri.

October 1, 2020 · DeviceView details →
Class IITerminated

CS011 GNR PNA FISH Control Slide, manufactured as a component of the CS011-10 GNR PNA FISH Control Slide kit . In-Vitro Diagnostic The CS011 GNR Traffic Light Control Slide provides a positive and negative control for the KT011 GNR Traffic Light PNA FISH kit. GNR Traffic Light PNA FISH provides rapid identification of E. coli, K. pneumoniae and P. aeruginosa directly from Gram-negative blood cultures

Opgen Inc

May show diminished performance prior to its established expiration date resulting in an invalid control result for the KTOll GNR PNA FISH Test

March 18, 2019 · DeviceView details →
Class IITerminated

Microbiologics QC Sets and Panels: Helix Elite. Extended Enteric Bacterial Verification Panel (Inactivated Pellet) includes 21 pellets each comprised of the following 8 organisms: 1. S. Typhimurium derived from NCTC 74, 2. S. sonnei derived from NCTC 12984, 3. E. coli derived from CDC 2010C-3114 (STEC), 4. C. jejuni derived from NCTC 11322, 5. P. shigelloides derived from NCTC 10363, 6. Y. enterocolitica derived from NCTC 11174, 7. E. coli derived from NCTC 11602 (ETEC), 8. V. parahaemolyticus derived from NCTC 13209

Microbiologics Inc

Real-time shelf life testing failed at 24 months

June 6, 2017 · DeviceView details →
Class IITerminated

Hardy Diagnostics MacConkey Agar with CiPRP, 1ug/ml Container type: 15x100mm monoplate packaged: 10 plates/sleeve Product Usage: MacConkey Agar with Ciprofloxacin is used as a screening medium for the selective isolation of Ciprofloxacin-resistant E. coli from clinical samples.

Hardy Diagnostics

Hardy Diagnostics is recalling MacConkey Agar with Ciprofloxacin, Brain Heart Infusion Broth with Ciprofloxacin 1 ug, MDR Acinetobacter, BEA with Azide and Vancomycin, BEA Agar with Vancomycin, Gentamicin, and Amphotericin B, BEA Broth with Vancomycin, and VRE Broth due to lack of 510(k) clearance.

June 26, 2015 · DeviceView details →
Class IITerminated

The Verigene Enteric Pathogens Nucleic Acid Test (EP) is a multiplexed, qualitative test for simultaneous detection and identification of common pathogenic enteric bacteria and genetic virulence markers from liquid or soft stool preserved in Cary-Blair media, collected from individuals with signs and symptoms of gastrointestinal infection. The test is performed on the automated Nanosphere Verigene System utilizing reverse transcription (RT), polymerase chain reaction (PCR), and array hybridization to detect specific gastrointestinal microbial nucleic acid gene sequences associated with the following pathogenic bacteria: - Campylobacter Group (comprised of C. coli, C. jejuni, and C. lari), - Salmonella species, - Shigella species (including S. dysenteriae, S. boydii, S. sonnei, and S. flexneri), - Vibrio Group (comprised of V. cholerae and V. parahaemolyticus), - Yersinia enterocolitica. In addition, EP detects the Shiga toxin 1 gene and Shiga toxin 2 gene virulence markers. Shiga toxin producing E. coli (STEC) typically harbor one or both genes that encode for Shiga Toxins 1 and 2. EP is indicated as an aid in the diagnosis of specific agents of gastrointestinal illness, in conjunction with other clinical, laboratory, and epidemiological information; however, is not to be used to monitor these infections. EP also aids in the detection and identification of acute gastroenteritis in the context of outbreaks. Due to the limited number of positive specimens collected for certain organisms during the prospective clinical study, performance characteristics for Yersinia enterocolitica, Vibrio Group and Shigella species were primarily established with contrived specimens. Concomitant culture is necessary for organism recovery and further typing of bacterial agents. EP results should not be used as the sole basis for diagnosis, treatment, or other patient management decisions. Confirmed positive results do not rule out co-infection with other organisms that are not detected by this test, and may not be the sole or definitive cause of patient illness. Negative EP results in the setting of clinical illness compatible with gastroenteritis may be due to infection by pathogens that are not detected by this test or non-infectious causes such as ulcerative colitis, irritable bowel syndrome, or Crohn's disease.

Nanosphere, Inc.

Nanosphere has received several reports relating to an increased rate of Processing Errors during procedures performed on the Processor SP caused by Tips in Tip Holder Assemblies for the following products and lots of Extraction Trays.

October 10, 2013 · DeviceView details →
Class IITerminated

AdvanDx E. coli/P. aeruginosa PNA FISH, In Vitro Diagnostic Culture Identification Kit for Escherichia coli and Pseudomonas aeruginosa Catalog Number : KT007 Usage: E. coli/P. aeruginosa PNA FISH is a multicolor, qualitative nucleic acid hybridization assay intended for identification of Escherichia coli and Pseudomonas aeruginosa on smears of positive blood cultures containing Gram-negative rods. The E.coli/P. aeruginosa PNA FISH assay is indicated for use as an aid in the diagnosis of E. coli and/or P. aeruginosa bacteremia.

Advandx Inc

Some strains of Pseudomonas putida cross-react with the P. aeruginosa PNA probe used in E. coli/P. aeruginosa PNA FISH (KT007) due to a sequence similarity resulting in a cross-reaction that may produce a red-positive signal

September 14, 2012 · DeviceView details →