Class IITerminated

Sensus Healthcare Inc, SRT-100 Vision IPX 0, HFUS Module IPX 1, with software version 1.9.2; Superficial X-ray Radiation Therapy System with Ultrasonic Imaging Capabilities

Sensus Healthcare, Inc.

When the user pauses the beam delivery, the dose timer is reset (to zero), and as a result may deliver an unexpected dose to the patient.

February 10, 2023 · DeviceView details →
Class ITerminated

BALLARD* ACCESS Closed Suction System for Neonates/Pediatrics, Elbow Manifold.

Avanos Medical, Inc.

Potential for product manifold to crack during use on patients, possibly causing leaks in the respiratory circuit and can lead to the patient receiving inadequate ventilation.

February 3, 2023 · DeviceView details →
Class ITerminated

BALLARD ACCESS Closed Suction System for Neonates/Pediatrics, Y-Manifold.

Avanos Medical, Inc.

Potential for product manifold to crack during use on patients, possibly causing leaks in the respiratory circuit and can lead to the patient receiving inadequate ventilation.

February 3, 2023 · DeviceView details →
Class IITerminated

Avanos Ballard Oral Care Swab, Bulk Packed, Product Codes: a) 12241, b) 12243, c) 12251

Avanos Medical, Inc.

Incorrect expiration date.

February 3, 2023 · DeviceView details →
Class IITerminated

Mammotome MammoStar Biopsy Site Identified, REF STAR1401

Carbon Medical Technologies, Inc.

The label incorrectly identifies the product as STAR1401, a 1x3mm Barbell shaped marker pre-loaded in a 14 gauge needle, while the packaging contains STAR1402, a 1x5mm Tribell shaped marker pre-loaded in a 14 gauge needle.

December 16, 2022 · DeviceView details →
Class IITerminated

DeRoyal ORGAN RECOVERY PACK PGYBK, a) REF 89-9004.09 and b) 89-9004.10

DeRoyal Industries Inc

DeRoyal is recalling certain lots of surgical procedure pack products that contain a Medtronic Non-Absorbable Suture. The recall is due to Medtronic determining a manufacturing error in the packaging of the non-absorbable sutures that may cause a gap or wrinkle in the breather seal resulting in a sterile barrier breach.

December 12, 2022 · DeviceView details →
Class ITerminated

SHIP KIT, LIFESPARC, CONTROLLER AND ACCESSORIES - 5900-0000; SHIP KIT, LIFESPARC, CONTROLLER ONLY - 5900-0001. Component of LifeSPARC System, used to pump the blood through an extracorporeal circuit.

Cardiac Assist, Inc

A software update (v1.1.5) has been developed to address the issue of Critical Failure which can occur on the LifeSPARC Controller. The Critical Failure was first addressed in the firm's recall initiated July 21, 2022. During the Critical Failure, the software freezes or crashes and the screen does not display data.

December 5, 2022 · DeviceView details →
Class IITerminated

Remington MEDICAL, Automatic Cutting Needle, 18ga (1.3mm) x 20cm, REF NAC-1820M (1)

Remington Medical, Inc.

The stylet is longer than specified on the label

December 2, 2022 · DeviceView details →
Class IITerminated

ActiveAid 922, Shower/Commode Chair

Altimate Medical, Inc.

Device manufactured with a component with affects the foldability of the frame, not allowing it to be secured by the frame strap in the folded position.

November 30, 2022 · DeviceView details →
Class IITerminated

DeRoyal Tonsillectomy Tray, REF 89-10698.01

DeRoyal Industries Inc

DeRoyal is recalling certain lots of surgical procedure pack products that contain a ConMed Foot Controlled Electrosurgical Suction Coagulator. The recall is due to ConMed receiving reports that the suction ports may be occluded on the affected devices. If this occurs, the affected devices will not be able to perform the suction function during use.

November 28, 2022 · DeviceView details →
Class ITerminated

RSDL (Reactive Skin Decontamination Lotion) Kit, NSN 6505-21-912-5229. Used to remove and/or neutralize chemical warfare agents and T-2 Toxin from the skin.

Emergent Protective Products USA Inc

Complaints of leaking packets were received.

November 24, 2022 · DeviceView details →
Class IITerminated

MobiCT-32 AIRO Mobile CT Scanner, Cat. No. MobiCT-32, mobile computed tomography (CT) system, software version 2.1.1

Mobius Imaging, LLC

Stryker received a report of a battery fire involving an Airo TruCT unit previously subjected to bypass charging. The firm is notifying customers with units whose battery monitoring systems were bypassed to charge the batteries; the batteries in these units require replacing.

November 18, 2022 · DeviceView details →
Class IITerminated

Foot Controlled Electrosurgical Suction Coagulator, Electrosurgical Suction Coagulator 10FR, Catalog Number 130187

ConMed Corporation

Suction ports may potentially be occluded on the affected devices. If this occurs, the affected devices will not be able to perform the suction function during use, which could cause a delay in procedure and could require another device to be used.

November 18, 2022 · DeviceView details →
Class IIITerminated

R&D CBC-3D Hematology Control: (1) CBC-3D Normal Pack Hematology Control, REF 3D501, containing 10 x 2.0mL Control N; (2) CBC-3D TRI PACK Hematology Control, REF 3D503, containing 4 x 2.0 mL Controls L, N, and H; (3) CBC-3D for Mythic 18 Hematology Control, REF 3D503RX, containing 2 x 2.0 mL each Controls L, N, and H; (4) CBC-3D For MINDRAY Hematology Control, REF 3D506, containing 2 x 3.0 mL each Controls L, N, and H; (5) CBC-3D For MINDRAY Hematology Control, REF 3D506US, containing 2 x 3.0 mL each Controls L, N, and H; (6) CBC-3D TRI PACK Hematology Control, REF 3D507, containing 4 x 2.0 mL each Controls L, N, and H; (7) CBC-3D TRI PACK Hematology Control, REF 3D508, containing 2 x 2.0 m each Controls L, N, and H; (8) CBC-3D For ABACUS, REF D3D02 Hematology Control, containing 2 x 3.0 mL each Controls L, N, and H; (9) CBC-3D For ABACUS Hematology Control, REF D3D04, containing 4 x 3.0 mL each Controls L, N, and H. Loose tubes labeled CBC-3D Hematology Control in 2.0mL and 3.0mL sizes. OEM/Own-label distributor labels: (1) Alere 380 Hemo Control (L-N-H), REF AL35004-KIT, containing 2 x 3.0 mL each Controls L, N, and H; Kit lot #B1122; control lot #B1122N, no UDI (2) diatron Diacon 3 Hematology Control, Normal Level, 3.0 mL tubes, lot #B1122N (3) diatron Diacon 3 Hematology Control, REF DN35002-SET, containing 6 x 3.0 mL Control N, kit lot #B1122, control lot #B1122N (4) diatron Diacon 3 Hematology Control, REF DN35004-KIT, containing 2 x 3.0 mL each Controls L, N, and H, kit lot #B1122, Normal control lot #B1122N. (5) Elite 3 HEM Control Normal, REF HEM00014, containing 6 x 3.0 mL Normal controls, kit lot #B1122, control lot #B1122N; (6) Erba H3 CON N, REF HEM00034, 3 mL vials, lot #E1122N, exp. 2023-02-10 (7) Horiba Medical Minotrol 16 Whole Blood Hematology Control, Cat. #5300000277, containing 3 x 2.5mL tubes (1 each Control 1, Control 2 (Normal), and Control 3; Cat. #5300000278, containing 6 x 2.5mL tubes (2 each Control 1, Control 2 (Normal), and Control 3; and Cat. #5300000283, containing 12 x 2.5mL tubes (4 each Control 1, Control 2 (Normal), and Control 3; kit lot #MX438, exp. 2023-01-05, Control 2 lot #MX438N. (8) 2022 3rd Test Event, CBC PLT 3 PART DIFF 2022-912-3D; and 2022 3rd Test Event, CBC PLT 3 PART DIFF 2022-914-3D. (9) mindray BC-3D, P/N 040-001423-00. (10) MINDRAY BC-3D CONTROL, REF BC3D01, containing 1 x 3.0 mL Controls L, N, and H; REF BC3D02, containing 2 x 3.0 mL Controls L, N, and H; and REF BC3D6N, containing 6 x 3.0 mL Control N; kit lot #B1122, control lot #B1122N. (11) MINDRAY BC-3D CONTROL, REF BC3D02US, containing 2 x 3.0 mL Level L, N, and H, kit lot number B1122, control lot #B1122N. (12) Nihon Kohden MEK-3D Hematology Control, REF 3DN03, containing MEK-3DN x 3 tubes; REF 3DN06, containing MEK-3DN x 6 tubes; and REF 3DN12, containing MEK-3DN x 12 tubes, kit lot #B22Y, control lot #B22YN. (13) Nihon Kohden MEK-3DN Normal Hematology Control tubes, 2.0 mL, lot #B22YN. (14) Orphee MYT-3D, REF MYT301, containing 2 x 2.5 mL Control N; REF MYT302, containing 2 x 2.5 mL each Controls L, N, and H; REF MYT304N, containing 4 x 2.5 mL Control N; REF 306N, containing 6 x 2.5 mL Control N; kit lot #B1122, control lot #B1122N; Myt-3D VET, REF MYT303-VET, containing 1 x 2.5 mL each Control L, N, and H. (15) Siemens ADVIA 360 Control, REF 11170853, containing 2 x 3.0 mL each Controls Low, Normal & High, kit lot #B0822, GTIN 00630414600833, control lot #B1122N. (16) URIT HQ-3DIFF, REF 5411000306, containing 2 x 3.0 mL each Controls L, N, and H, kit lot #B1122, control lot #B1122N; URIT HQ-3DIFF Hematology Control N tubes, 3.0 mL, lot #B1122N. (17) Woodley Haematology Control, REF WD1154, containing 6 x 2.0 mL Control N; and REF WD1154A, containing 2 x 2.0 mL each Controls L, N, and H, kit lot number B1122, control lot #B1122N;

R & D Systems, Inc.

For one lot of CBC-3D Hematology Control, the Normal Level may exhibit hemolysis or deterioration due to microbial contamination.

November 7, 2022 · DeviceView details →
Class IITerminated

Medical Action INDUSTRIES INC. Port a Cath Kit REF 58647D, cardiac catheter introduction kit

Medical Action Industries, Inc. 306

XXX

November 4, 2022 · DeviceView details →
Class IITerminated

IgM Immunoturbidimetric Assay-In vitro determination of IgA and IgM in serum and plasma Catalog Number: IM3834

Randox Laboratories Ltd.

Update to the carryover avoidance technical bulletin to detail that IgA and IgM assays should not be run immediately after Fructosamine Catalogue Number FR3133 or FR4030 on the RX instruments testing order. Can lead to an elevation in Quality Control and Patient results of up to +13% for lgA and +51% for lgM respectively, which may lead to a delay in running patient samples or erroneous elevated test results

November 1, 2022 · DeviceView details →
Class IITerminated

IgA Immunoturbidimetric Assay- In vitro determination of IgA and IgM in serum and plasma Catalog Number: IA3832

Randox Laboratories Ltd.

Update to the carryover avoidance technical bulletin to detail that IgA and IgM assays should not be run immediately after Fructosamine Catalogue Number FR3133 or FR4030 on the RX instruments testing order. Can lead to an elevation in Quality Control and Patient results of up to +13% for lgA and +51% for lgM respectively, which may lead to a delay in running patient samples or erroneous elevated test results

November 1, 2022 · DeviceView details →
Class IITerminated

Unity Total Knee System. Used for knee prosthesis in total knee replacement

Corin Ltd

The internal packaging system for devices may have damage to the blisters potentially damaging the device or compromising the sterility of the packaging.

October 31, 2022 · DeviceView details →
Class IITerminated

Baxter Electrocardiograph, ELI 380 -DCS21

Baxter Healthcare Corporation

One ELI 380 Electrocardiograph intended to be used for a pilot program was shipped to a customer by mistake on 26 October 2022.

October 31, 2022 · DeviceView details →
Class IITerminated

NextAR Shoulder Surgical Technique, Shoulder NextAR RSA Platform, CT based computer-assisted surgical navigation platform used to perform a reverse shoulder arthroplasty on the glenoid

Medacta Usa Inc

A warning has been added to the Surgical Technique for NextAR Shoulder, advising verification of suitable patient conditions prior to placement of the NextAR Shoulder Target Holder: WARNING Target fixation requires adequate coracoid bone stability. Osteoporosis, weakness of the coracoid process, or other deficiencies, could lead to adverse events including bone fracture. Verify that the coracoid bone and relevant patient conditions are suitable before proceeding.

October 27, 2022 · DeviceView details →