Civic Data
FDA RecallsUSDA RecallsAbout

FDA Recalls

  • Food recalls
  • Drug recalls
  • Device recalls

USDA Recalls

  • All USDA recalls
  • Poultry recalls
  • Meat recalls
  • Egg recalls

About

  • About us
  • FDA guides
  • USDA guides
  • Data sources
  • Privacy policy

Data

  • OpenFDA API
  • USDA FSIS

© 2026Civic Data · Data sourced from OpenFDA and USDA FSIS · Not affiliated with the U.S. Food and Drug Administration or the U.S. Department of Agriculture · Always verify against official sources before acting

  1. FDA Recalls
  2. ›Device Recalls

FDA Device Recalls

Recalls of medical devices, diagnostic equipment, implants, and surgical instruments.

Classification
AllClass IClass IIClass III
Status
AllOngoingCompletedTerminated
Date
All timePast 30 daysPast 12 months

Showing 3541–3560 of 39,430 recalls

Class IIOngoing

Brand Name: Rover Product Name: Mobile X-ray System Model/Catalog Number: MXU-RV71, MXU-RV35 Product Description: Rover Mobile X-rays System ("Rover") is a mobile imaging system that incorporates a self-contained X-ray generator, imaging display and software for acquiring medical diagnostic images outside a standard X-ray room. It is designed specifically for Digital Radiography (DR) with vendor-supported detectors. The Rover is designed to perform radiographic X-ray examinations for disease/injury detection, diagnosis, medical and surgical treatment planning, and therapy monitoring, where patient condition contraindicates transport to a fixed X-ray unit The Rover can be used on pediatric and adult patients, in all patient treatment areas Component: N/A

Micro-X Ltd.

Potential for internal fastening mechanism within generator of mobile x-Ray to fail.

April 4, 2025 · DeviceView details →
Class IIOngoing

KliniTray. KlinioTray. Tissue resection margin examination board/small. Model Number: 2001105-F The medical device KliniTrayTM is a system for the precise monitoring, recording and visualization of alignment during surgical procedures. It ensures the exact orientation and positioning of tissue to be removed in the patient's body, enabling improved surgical precision and patient safety.

Klinika Mdical Gmb

Potential for microbial contamination.

April 4, 2025 · DeviceView details →
Class IIOngoing

Posterior Femoral Augment; Item Numbers: (1) 880-310/11 (Sz. 0 - cemented sm), (2) 880-310/21 (Sz. 0 - cemented lg), (3) 880-311/11 (Sz. 1-2 - cemented sm), (4) 880-311/21 (Sz. 1-2 - cemented lg), (5) 880-313/11 (Sz. 3-4 - cemented sm), (6) 880-313/12 (Sz. 3-4 - cemented md), (7) 880-313/21 (Sz. 3-4 - cemented lg), (8) 880-313/22 (Sz. 3-4 - cemented x-lg), (9) 880-315/11 (Sz. 5-6 - cemented sm), (10) 880-315/12 (Sz. 5-6 - cemented md), (11) 880-315/21 (Sz. 5-6 - cemented lg), (12) 880-315/22 (Sz. 5-6 - cemented x-lg), (13) 880-317/11 (Sz. 7-8 - cemented sm), (14) 880-317/12 (Sz. 7-8 - cemented md), (15) 880-317/21 (Sz. 7-8 - cemented lg), (16) 880-317/22 (Sz. 7-8 - cemented x-lg), (17) 880-319/11 (Sz. 9-10 - cemented sm), (18) 880-319/12 (Sz. 9-10 - cemented md), (19) 880-319/21 (Sz. 9-10 - cemented lg), (20) 880-319/22 (Sz. 9-10 - cemented x-lg).

Waldemar Link GmbH & Co. KG (Mfg Site)

The device was delivered with a preassembled Femoral Augment screw that was missing its thread.

April 3, 2025 · DeviceView details →
Class IIOngoing

Atalante X, Powered Exoskeleton. Atalante X is intended to perform ambulatory functions and mobility exercises, hands-free, in rehabilitation institutions under the supervision of a trained operator.

WANDERCRAFT SAS

Potential for exoskeleton to lose lateral balance and cause patient to fall.

April 3, 2025 · DeviceView details →
Class IIOngoing

Tibial Augment; Item Numbers: (1) 880-331/11 (Sz. 1-2 - cemented x-sm), (2) 880-331/12 (Sz. 1-2 - cemented sm), (3) 880-331/13 (Sz. 1-2 - cemented md), (4) 880-331/21 (Sz. 1-2 - cemented lg), (5) 880-331/22 (Sz. 1-2 - cemented x-lg), (6) 880-331/23 (Sz. 1-2 - cemented xx-lg), (7) 880-333/11 (Sz. 3-4 - cemented x-sm), (8) 880-333/12 (Sz. 3-4 - cemented sm), (9) 880-333/13 (Sz. 3-4 - cemented md), (10) 880-333/21 (Sz. 3-4 - cemented lg), (11) 880-333/22 (Sz. 3-4 - cemented x-lg), (12) 880-333/23 (Sz. 3-4 - cemented xx-lg), (13) 880-335/11 (Sz. 5-6 - cemented x-sm), (14) 880-335/12 (Sz. 5-6 - cemented sm), (15) 880-335/13 (Sz. 5-6 - cemented md), (16) 880-335/21 (Sz. 5-6 - cemented lg), (17) 880-335/22 (Sz. 5-6 - cemented lg), (18) 880-335/23 (Sz. 5-6 - cemented xx-lg), (19) 880-337/11 (Sz. 7-8 - cemented x-sm), (20) 880-337/12 (Sz. 5-6 - cemented sm), (21) 880-337/13 (Sz. 7-8 - cemented md), (22) 880-337/21 (Sz. 7-8 - cemented lg), (23) 880-337/22 (Sz. 7-8 - cemented x-lg), (24) 880-337/23 (Sz. 7-8 - cemented xx-lg), (25) 880-339/11 (Sz. 9-10 - cemented x-sm), (26) 880-339/12 (Sz. 9-10 - cemented sm), (27) 880-339/13 (Sz. 9-10 - cemented md), (28) 880-339/21 (Sz. 9-10 - cemented lg), (29) 880-339/22 (Sz. 9-10 - cemented x-lg), (30) 880-339/23 (Sz. 9-10 - cemented xx-lg);

Waldemar Link GmbH & Co. KG (Mfg Site)

The device was delivered with a preassembled Femoral Augment screw that was missing its thread.

April 3, 2025 · DeviceView details →
Class IIOngoing

Enhanced Verify Evaluation Handset (CFN HH90130FA)

Medtronic Neuromodulation

Evaluation handsets may not be able to communicate with the neurostimulator due to handsets having a faster processing speed than prior handsets. An inability to connect may cause the therapy to stop being delivered and a system error will be displayed. Patient may experience return of underlying disease symptoms (e.g. overactive bladder, urinary retention, or fecal incontinence) based on their response to stimulation during the evaluation period.

April 3, 2025 · DeviceView details →
Class IIOngoing

Distal Femoral Augment; Item Numbers: (1) 880-300/11 (Sz. 0 - cemented sm), (2) 880-300/21 (Sz. 0 - cemented lg), (3) 880-301/11 (Sz. 1-2 - cemented sm), (4) 880-301/21 (Sz. 1-2 - cemented lg), (5) 880-303/11 (Sz. 3-4 - cemented sm), (6) 880-303/12 (Sz. 3-4 - cemented md), (7) 880-303/21 (Sz. 3-4 - cemented lg), (8) 880-303/22 (Sz. 3-4 - cemented x-lg), (9) 880-305/11 (Sz. 5-6 - cemented sm), (10) 880-305/12 (Sz. 5-6 - cemented md), (11) 880-305/21 (Sz. 5-6 - cemented lg), (12) 880-305/22 (Sz. 5-6 - cemented x-lg), (13) 880-307/11 (Sz. 7-8 - cemented sm), (14) 880-307/12 (Sz. 7-8 - cemented md), (15) 880-307/21 (Sz. 7-8 - cemented lg), (16) 880-307/22 (Sz. 7-8 - cemented x-lg), (17) 880-309/11 (Sz. 9-10 - cemented sm), (18) 880-309/12 (Sz. 9-10 - cemented md), (19) 880-309/21 (Sz. 9-10 - cemented lg), (20) 880-309/22 (Sz. 9-10 - cemented x-lg).

Waldemar Link GmbH & Co. KG (Mfg Site)

The device was delivered with a preassembled Femoral Augment screw that was missing its thread.

April 3, 2025 · DeviceView details →
Class IIOngoing

MAGEC 2 Rod, 5.0mm 90mm Standard; Version/Model: MC2-5090S;

Globus Medical, Inc.

Devices for the affected lot were not assembled according to product specifications. The distraction rod outer diameter was assembled with a 5.5mm rod versus the required 5.0mm.

April 3, 2025 · DeviceView details →
Class IIOngoing

L-Shaped Femoral Augment; Item Numbers: (1) 880-320/12 (Sz. 0 - cemented sm), (2) 880-320/22 (Sz. 0 - cemented lg), (3) 880-321/12 (Sz. 1-2 - cemented sm), (4) 880-321/22 (Sz. 1-2 - cemented lg), (5) 880-323/13 (Sz. 3-4 - cemented sm), (6) 880-323/23 (Sz. 3-4 - cemented lg), (7) 880-325/13 (Sz. 5-6 - cemented sm), (8) 880-325/23 (Sz. 5-6 - cemented lg), (9) 880-327/13 (Sz. 7-8 - cemented sm), (10) 880-327/23 (Sz. 7-8 - cemented lg), (11) 880-329/13 (Sz. 9-10 - cemented sm), (12) 880-329/23 (Sz. 9-10 - cemented lg).

Waldemar Link GmbH & Co. KG (Mfg Site)

The device was delivered with a preassembled Femoral Augment screw that was missing its thread.

April 3, 2025 · DeviceView details →
Class IIOngoing

Washer Disinfector Aquadis 56; Model Number: 56M

Getinge Disinfection Ab

The frequency inverter is not programmed by supplier according to specification which causes the circulation pump to start earlier than expected, resulting in additional wear and tear, earlier than expected, on the axial seal in the pump housing.

April 2, 2025 · DeviceView details →
Class IIOngoing

Washer Disinfector Aquadis 56; Model Number: 56A

Getinge Disinfection Ab

The frequency inverter is not programmed by supplier according to specification which causes the circulation pump to start earlier than expected, resulting in additional wear and tear, earlier than expected, on the axial seal in the pump housing.

April 2, 2025 · DeviceView details →
Class IIOngoing

Biomet 3i Certain-compatible 4.1 mm Milled Ti Abutment REF 9001767-F Preat milled Abutments are intended to be used in conjunction with endosseous dental implants in the maxillary or mandibular arch to provide support for single-unit or multi-unit prosthetic restorations.

Preat Corp

Due to manufacturing issues, abutment products were manufactured with screw seat located too high, which may cause the mating screw to have a shorter engagement length into the associated implant.

April 2, 2025 · DeviceView details →
Class IIOngoing

HistoCore PELORIS 3, Model/Catalog Number: 45.0005/45.7512.501 A11, Software Version: 3.4.0. The HistoCore PELORIS 3 Rapid Tissue Processor is a dual retort rapid tissue processor used to prepare tissue samples.

Leica Biosystems Melbourne Pty Ltd

There is a leakage issue associated with the tubing in the manifold of the instrument.

April 2, 2025 · DeviceView details →
Class IIOngoing

myQA iON; Article Number: MQ10-000;

IBA Dosimetry GmbH

Wrong analysis results can occur if the user creates two structures with the same name, except for one differing by a special character.

April 1, 2025 · DeviceView details →
Class IIOngoing

Philips Brilliance CT Big Bore, Software Version 4.8.0.10430. Computed Tomography X-Ray System.

Philips North America Llc

Unintended motion issues related to Interventional Control that may lead to collision of the Gantry/table with the operator or patient.

April 1, 2025 · DeviceView details →
Class IIOngoing

3.0 Liter Disposable Set (4 sets/case). Model Number: 903-00032. The P/N 903-00032 consists of 4 Large Volume Reservoirs (P/N 903-00018) and 4 Heat Exchanger/Patient Line set (P/N 403-00382). The two components are packaged separately in individual pouches and placed in the same case for shipment. The female quick connector that may be cracked is located on the Heat Exchanger/Patient Line set.

Belmont Instrument LLC

Potential crack in the female connector located on the Heat Exchanger/patient line set, which will lead to a fluid leak through the crack during priming of the Rapid Infuser.

March 31, 2025 · DeviceView details →
Class IIOngoing

Halyard CHRIST SUTURE KIT. General Procedure Tray Convenience Kit

AVID Medical, Inc.

An issue with a raw material used to coat some surgical needles that may result in diminished performance and/or removal of some silicone needle coating during use.

March 31, 2025 · DeviceView details →
Class IIOngoing

Ultrasonic Cleaning Systems Triton 36 Model Number 6003000804 Triton 72 Model Number 6003000805 Ultrasonic cleaning system

Ultra Clean Systems, Inc.

During routine preventative maintenance checks, it was revealed that carbon filter sensors were breaking down due to electrochemical degradation.

March 31, 2025 · DeviceView details →
Class IIOngoing

Halyard RAPIDES E-PACK. Cardiovascular Procedure Convenience Kit.

AVID Medical, Inc.

An issue with a raw material used to coat some surgical needles that may result in diminished performance and/or removal of some silicone needle coating during use.

March 31, 2025 · DeviceView details →
Class IIOngoing

Hyperthermia Pump Procedure Kit. Model Number: 902-00045. Sterile, single-use, disposable set used with the Hyperthermia Pump. The Hyperthermia Procedure kit (P/N 902-00045) consists of 4.4 Liter Reservoir (P/N 902-00034P), Heat Exchanger set (P/N 902-00006P) and HP Procedure Pack (P/N 902-00048P). The three components are packaged separately in individual pouches and boxes and placed in the same case for shipment. All three components are connected prior to use. The female quick connector that may be cracked is located on the Heat Exchanger set (P/N 902-00006P).

Belmont Instrument LLC

Potential crack in the female connector located on the Heat Exchanger in the set, which will lead to a fluid leak through the crack during priming of the rapid infuser.

March 31, 2025 · DeviceView details →
← PreviousPage 178 of 1,972Next →