  2. ›Device Recalls

FDA Device Recalls

Recalls of medical devices, diagnostic equipment, implants, and surgical instruments.

Classification
AllClass IClass IIClass III
Status
AllOngoingCompletedTerminated
Date
All timePast 30 daysPast 12 months

Showing 3301–3320 of 39,430 recalls

Class IIOngoing

My3D Personalized Solutions Humeral Cup, Model Number: C24-0223-0003. It is a component of a Custom Constrained Shoulder Arthroplasty Device

Onkos Surgical, Inc.

Required inspections were not performed on finished product prior to release and distribution.

May 20, 2025 · DeviceView details →
Class IIOngoing

ColoSense Test Kit, Part No. 80-001, component of ColoSense test

Geneoscopy, Inc.

Multiple plate failures documented as a result of the Low Positive Template Control being too high and out of range using the affected lot of ColoSense Test Kit.

May 20, 2025 · DeviceView details →
Class IIOngoing

PRIMA 4MM ECCENTRICAL ADAPTOR WITH SCREW, REF:1367.15.704, Sterile

Limacorporate S.p.A

There is the potential that the eccentrical adaptor with screw, black laser marking, use to identify the position may be missing.

May 19, 2025 · DeviceView details →
Class IIOngoing

PRIMA 2MM ECCENTRICAL ADAPTOR WITH SCREW REF: 1367.15.702, Sterile

Limacorporate S.p.A

There is the potential that the eccentrical adaptor with screw, black laser marking, use to identify the position may be missing.

May 19, 2025 · DeviceView details →
Class IIOngoing

Brand Name: Hummingbird Product Name: Stimulated EMG Kit with Hummingbird - Model/Catalog Number: REF I-D-BMF90, 1 Single-Use Bipolar Minifork Stimulation Probe, 90mm, and 1 Green Ground Needle ; REF 1-D-BMF90-5, lot number 050925219, expiration 2028-11-30 I-D-BMF90-5 Stimulated EMG Kit with Hummingbird - Box of 5 Kits - Each Kit Includes: 1 Single-Use Bipolar Minifork Stimuation Probe, 90mm, and 1 Green Ground Needle

Neurovision Medical Products Inc

Product packaging contains the wrong part number and kit contents.

May 19, 2025 · DeviceView details →
Class IIOngoing

Brand Name: Q-Stop Product Name: Suture Retention Device Model/Catalog Number: QS Software Version: N/A Product Description: The DRS Vascular Q-Stop Suture Retention Appliance is a sterile, single-use, lightweight device made of biocompatible materials that can be easily installed within minutes to assist with venous access hemostasis. Component: No

Drs Vascular, Inc

XXX

May 16, 2025 · DeviceView details →
Class IIOngoing

GE Healthcare LOGIQ F R3 Ultrasound System, Model/Catalog Number 5943263, diagnostic ultrasound system

GE Medical Systems China Co., Ltd.

GE HealthCare has become aware that the Estimated Fetal Weight (EFW) measurement data feature on the Versana Premier R3 and LOGIQ F R3 series ultrasound systems can display previous obstetric patient data in the Whizz report. This could potentially lead to an incorrect clinical decision due to inaccuracy in the fetal size and growth calculation.

May 16, 2025 · DeviceView details →
Class IIOngoing

Brand Name: Cellex Photopheresis System Product Name: CELLEX Photopheresis Kit Model/Catalog Number: CLXUSA Software Version: Not Applicable Product Description: THERAKOS Photopheresis or extracorporeal photopheresis (ECP) is a photoimmune therapy where leukocytes are separated from whole blood via apheresis, combined with a photoactive drug (8-methoxypsoralen) and then exposed to ultraviolet A (UVA) light. All blood components, including the treated leukocytes, are returned to the patient. THERAKOS¿ Photopheresis utilizes the THERAKOS CELLEX System to combine cell separation and photoactivation into a single, closed and sterile circuit. The THERAKOS CELLEX Photopheresis System collects the buffy coat (leukocyte-enriched blood) from the patient in a discontinuous flow process and intermittently returns the remaining plasma and erythrocytes to the patient. The buffy coat is passed through the photoactivation module where the drug is activated with a precise amount of UVA light determined by the characteristics of the individual patient s buffy coat. After photoactivation, the buffy coat is immediately returned to the patient s bloodstream. Component: Not Applicable

THERAKOS DEVELOPMENT LIMITED

Increased difficulty in installing the centrifuge bowl onto the centrifuge bowl holder. Improper installation may cause the centrifuge bowl to dislodge, resulting in a broken bowl during the prime cycle or treatment phase, leading to a delay in patient treatment and blood loss.

May 16, 2025 · DeviceView details →
Class IIOngoing

GE Healthcare Versana Ultrasound Systems, sold under the following names and Model/Catalog Numbers: 1) Versana Premier R3 VS, Model/Catalog Number 5938558; 2) Versana Premier R3 VA, Model/Catalog Number 5938559; 3) Versana Premier Lotus 4PP, Model/Catalog Number 5938560; 4) Versana Premier Lotus 5PP, Model/Catalog Number 5938561; 5) Versana Premier R3 VA Vet, Model/Catalog Number 5946387; 6) Versana Premier R3 VS Vet, Model/Catalog Number 5946481. 7) Versana Premier R3 Expert, Model/Catalog Number 5946950; 8) Versana Premier R3, Model/Catalog Number 5946951; 9) Versana Premier R3 Pro, Model/Catalog Number 5946952; 10) Versana Premier R3 Elite, Model/Catalog Number 5946953; 11) Versana Premier R3 Plus, Model/Catalog Number 5946954; 12) Versana Premier R3 Ultra, Model/Catalog Number 5946955; 13) Versana Premier R3 Max, Model/Catalog Number 5946956; 14) Versana Premier R3 Super, Model/Catalog Number 5946957; 15) Versana Premier R3 VS India, Model/Catalog Number 5948398; 16) Versana Premier R3 VA India, Model/Catalog Number 5948399; diagnostic ultrasound system

GE Medical Systems China Co., Ltd.

GE HealthCare has become aware that the Estimated Fetal Weight (EFW) measurement data feature on the Versana Premier R3 and LOGIQ F R3 series ultrasound systems can display previous obstetric patient data in the Whizz report. This could potentially lead to an incorrect clinical decision due to inaccuracy in the fetal size and growth calculation.

May 16, 2025 · DeviceView details →
Class IIOngoing

Medline UMBILICAL TRAY W/3.5&5FR CATH, REF UVT1250

MEDLINE INDUSTRIES, LP - Northfield

There is a possible packaging defect impacting the outer Tyvec pouch that protects the sterile product.

May 15, 2025 · DeviceView details →
Class IIOngoing

Contamac, Nutrifill Physiologic formula, Contact Lens Insertion solution

Contamac Solutions, Inc.

Contact lens insertion solution may lack sterility.

May 15, 2025 · DeviceView details →
Class IIOngoing

interventional fluoroscopic x-ray system

Siemens Medical Solutions USA, Inc

In very rare situations, communication between the sensor measuring dose applied to the area and the corresponding software fails. As a result of the failure, the system may incorrectly report an application of a high dose.

May 15, 2025 · DeviceView details →
Class IIOngoing

interventional fluoroscopic x-ray system

Siemens Medical Solutions USA, Inc

In very rare situations, communication between the sensor measuring dose applied to the area and the corresponding software fails. As a result of the failure, the system may incorrectly report an application of a high dose.

May 15, 2025 · DeviceView details →
Class IOngoing

Broselow Pediatric Emergency Rainbow Tape (distribution by AirLife); REF 7700REA AirLife brand, 2025 Edition, and 36-23446 Rev 2 Print Version The Broselow Tape is a length- and weight-based reference tool specifically designed for pediatric emergency care.

SunMed Holdings, LLC

The impacted tape was manufactured with incorrect information on the tape. Incorrect values are printed in the Red zone, Orange zone, and Grey zone. Using the incorrect values in the Red zone could lead to shocking a patient with an excessive dose of joules, causing significant harm including burns, heart damage, and cardiac arrest. Incorrect values in the Orange zone could lead to overdosing the patient with sodium bicarbonate and cause metabolic alkalosis, electrolyte imbalances, tissue damage, and worsen respiratory status. Incorrect information in the Grey may lead to underdosing the patient with sodium bicarbonate and may cause reduced myocardial contractility, decreased response to vasopressors, and increased risk of dysrhythmia.

May 15, 2025 · DeviceView details →
Class IIOngoing

interventional fluoroscopic x-ray system

Siemens Medical Solutions USA, Inc

In very rare situations, communication between the sensor measuring dose applied to the area and the corresponding software fails. As a result of the failure, the system may incorrectly report an application of a high dose.

May 15, 2025 · DeviceView details →
Class IIOngoing

ARTIS is a family of dedicated angiography systems developed for single and biplane diagnostic imaging and interventional procedures including, but not limited to, pediatric and obese patients. Procedures that can be performed with the ARTIS family include cardiac angiography, neuro-angiography, general angiography, rotational angiography, multipurpose angiography and whole body radiographic/fluoroscopic procedures as well as procedures next to the table for i.e., patient extremities. This does not include projection radiography. Additional procedures that can be performed include angiography in the operating room, image guided surgery by X-ray, by image fusion, and by navigation systems. The examination table as an integrated part of the system can be used for X-ray imaging, surgery and interventions. ARTIS can also support the acquisition of position triggered imaging for spatial data synthesis.

Siemens Medical Solutions USA, Inc

In very rare situations, communication between the sensor measuring dose applied to the area and the corresponding software fails. As a result of the failure, the system may incorrectly report an application of a high dose.

May 15, 2025 · DeviceView details →
Class IOngoing

Beacon Tip 5.0 Fr Angiographic catheters are designed to facilitate diagnostic and therapeutic procedures. Catheters are available in various configurations. Configurations include different shaft lengths and tip curves and some catheters are manufactured with a hydrophilic coating. Refer to the product label for product specifications (e.g., catheter length, distal curve configuration).

Cook Incorporated

Cook Medical identified that catheters supplied in the affected device lots may experience tip separation.

May 15, 2025 · DeviceView details →
Class IOngoing

Brand Name: Optisite Arterial Cannula Product Name: Optisite Arterial Cannula Model/Catalog Number: OPTI16 Software Version: N/A Product Description: Cardiac cannula. The Edwards OptiSite Arterial Perfusion Cannluae provides or establishes arterial perfusion in the extracorporeal circuit for d 6 hours. Component: No.

Edwards Lifesciences, LLC

due to complaints received for 3mm to 4mm section wire exposed/protruding from the outside of the cannula body.

May 14, 2025 · DeviceView details →
Class IOngoing

Brand Name: FEM-FLEX II Product Name: Femoral Arterial Cannula Model/Catalog Number: FEMII016AS Software Version: N/A Product Description: The Edwards FEMFLEXII Femoral Perfusion Cannluae provides or establishes arterial perfusion in the extracorporeal circuit for d 6 hours. Component: No

Edwards Lifesciences, LLC

due to complaints received for 3mm to 4mm section wire exposed/protruding from the outside of the cannula body.

May 14, 2025 · DeviceView details →
Class IOngoing

Brand Name: FEM-FLEX II Product Name: Femoral Arterial Cannula Model/Catalog Number: FEMII018A Software Version: N/A Product Description: The Edwards FEMFLEXII Femoral Perfusion Cannluae provides or establishes arterial perfusion in the extracorporeal circuit for d 6 hours. Component: No

Edwards Lifesciences, LLC

due to complaints received for 3mm to 4mm section wire exposed/protruding from the outside of the cannula body.

May 14, 2025 · DeviceView details →