FDA Device Recalls

Recalls of medical devices, diagnostic equipment, implants, and surgical instruments.

Classification
AllClass IClass IIClass III
Status
AllOngoingCompletedTerminated
Date
All timePast 30 daysPast 12 months

Showing 2221–2240 of 39,430 recalls

Class IIOngoing

SAFE-T-FILL Plastic Blood Gas Capillary Tubes, 150 ¿L; Prepared with Balanced Heparin Model 06 0186 Product Description: A clear, plastic capillary blood collection tube coated with Heparin

ASP Global, LLC. dba Anatomy Supply Partners, LLC.

Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes.

September 26, 2025 · DeviceView details →
Class IIOngoing

Model: Incisive CT for Brazil SKD; Product Code (REF): 728146; Software Versions: 5.1.0.X & 5.1.1.X;

PHILIPS MEDICAL SYSTEMS

Issue 1: The potential for unintentional continued gantry/couch movement when a specific button series is used requiring use of manual stop. Issue 2. When performing a helical/Axial scan with ORI (Dose Right index)/ DOM (Dose Modulation), the WED (Water Equivalent Diameter) value might set itself to zero, and this may lead to an insufficient dose setting after the surview. If operator misses the insufficient dose and the WED value in User Interface and continues with the subsequent helical/Axial scans, then the obtained images will be noisy due to low dose setting. Issue 3: Due to a software failure, the ECG wave file is not saved. As a result, the cardiac offline image reconstruction fails due to the missing ECG wave file, and the user might rescan the patient. Issue 4: This issue is software fault in which the patient orientation will be changed to NULL under specific random scenarios resulting in radiation being delivered from the wrong orientation (surview scan) or in the wrong position (clinical scan) and will generate incorrect and undiagnosable surview/clinical images. Patients may be rescanned for surview and/or clinical images. Issue 5: During scanning, the preview image display is not consistent, the images are not arriving at a fixed rate, skipping images from time to time during scanning. The obtained images might not support making the clinical diagnosis and the user might decide to re-scan the patient. Issue 6: If a user presses the left and middle/right mouse buttons together or afterwards in a short time, both commands are executed and an incorrect auto ROI is created. This ROI coordinates won t be assigned as the object is empty. As a result, the threshold of contrast level will not be reached in the UI and this will prevent the system from automatically triggering the subsequent clinical scan. There is potential safety risk identified for additionally tracker shots and/or rescan of a patient when the clinical scan is not triggered. This issue only affects the manual ROI process.

September 25, 2025 · DeviceView details →
Class IIOngoing

Covidien Signia" Small Diameter Curved Tip Intelligent Reload (45mm Vascular/Thin); BOX LOBECTOMIA VATS 3D; CFN: BOX06170V4;

Covidien, LP

A manufacturing issue could lead to a malformed cover tube press which can lead to internal components' movement during firing - leading to the potential for uncontrolled motion.

September 25, 2025 · DeviceView details →
Class IIOngoing

Model: CT 5300; Product Code (REF): 728285; Software Versions: 5.1.0.X & 5.1.1.X;

PHILIPS MEDICAL SYSTEMS

Issue 1: The potential for unintentional continued gantry/couch movement when a specific button series is used requiring use of manual stop. Issue 2. When performing a helical/Axial scan with ORI (Dose Right index)/ DOM (Dose Modulation), the WED (Water Equivalent Diameter) value might set itself to zero, and this may lead to an insufficient dose setting after the surview. If operator misses the insufficient dose and the WED value in User Interface and continues with the subsequent helical/Axial scans, then the obtained images will be noisy due to low dose setting. Issue 3: Due to a software failure, the ECG wave file is not saved. As a result, the cardiac offline image reconstruction fails due to the missing ECG wave file, and the user might rescan the patient. Issue 4: This issue is software fault in which the patient orientation will be changed to NULL under specific random scenarios resulting in radiation being delivered from the wrong orientation (surview scan) or in the wrong position (clinical scan) and will generate incorrect and undiagnosable surview/clinical images. Patients may be rescanned for surview and/or clinical images. Issue 5: During scanning, the preview image display is not consistent, the images are not arriving at a fixed rate, skipping images from time to time during scanning. The obtained images might not support making the clinical diagnosis and the user might decide to re-scan the patient. Issue 6: If a user presses the left and middle/right mouse buttons together or afterwards in a short time, both commands are executed and an incorrect auto ROI is created. This ROI coordinates won t be assigned as the object is empty. As a result, the threshold of contrast level will not be reached in the UI and this will prevent the system from automatically triggering the subsequent clinical scan. There is potential safety risk identified for additionally tracker shots and/or rescan of a patient when the clinical scan is not triggered. This issue only affects the manual ROI process.

September 25, 2025 · DeviceView details →
Class IOngoing

Brand Name: MEGA Ballast Distal Access Platform Product Name: Mega Ballast Model/Catalog Number: MEGABT09180, MEGABT09190, MEGABT091100, MEGABT091110 Software Version: N/A Product Description: The Mega Ballast 091 is designed with a semi-rigid proximal shaft and a highly flexible distal shaft. The design facilitates the advancement of the Mega Ballast to access the tortuous vasculature over a guidewire and a respective dilator. The outer surface of the Mega Ballast is coated with a hydrophilic coating to facilitate lubricity from tip to 40 cm proximal. The proximal end of the Mega Ballast incorporates a Luer fitting hub for the attachment of accessories. The Mega Ballast is provided sterile, non-pyrogenic, and is intended for single use only. Component: Not a component

BALT USA, LLC

Due to an identified manufacturing defect involving coating material lifting within the catheter's distal inner diameter/lumen.

September 25, 2025 · DeviceView details →
Class IIOngoing

Model: Incisive CT; Product Code (REF): (1) 728143, (2) 728144; Software Versions: 5.1.0.X & 5.1.1.X;

PHILIPS MEDICAL SYSTEMS

Issue 1: The potential for unintentional continued gantry/couch movement when a specific button series is used requiring use of manual stop. Issue 2. When performing a helical/Axial scan with ORI (Dose Right index)/ DOM (Dose Modulation), the WED (Water Equivalent Diameter) value might set itself to zero, and this may lead to an insufficient dose setting after the surview. If operator misses the insufficient dose and the WED value in User Interface and continues with the subsequent helical/Axial scans, then the obtained images will be noisy due to low dose setting. Issue 3: Due to a software failure, the ECG wave file is not saved. As a result, the cardiac offline image reconstruction fails due to the missing ECG wave file, and the user might rescan the patient. Issue 4: This issue is software fault in which the patient orientation will be changed to NULL under specific random scenarios resulting in radiation being delivered from the wrong orientation (surview scan) or in the wrong position (clinical scan) and will generate incorrect and undiagnosable surview/clinical images. Patients may be rescanned for surview and/or clinical images. Issue 5: During scanning, the preview image display is not consistent, the images are not arriving at a fixed rate, skipping images from time to time during scanning. The obtained images might not support making the clinical diagnosis and the user might decide to re-scan the patient. Issue 6: If a user presses the left and middle/right mouse buttons together or afterwards in a short time, both commands are executed and an incorrect auto ROI is created. This ROI coordinates won t be assigned as the object is empty. As a result, the threshold of contrast level will not be reached in the UI and this will prevent the system from automatically triggering the subsequent clinical scan. There is potential safety risk identified for additionally tracker shots and/or rescan of a patient when the clinical scan is not triggered. This issue only affects the manual ROI process.

September 25, 2025 · DeviceView details →
Class IIOngoing

Covidien Signia" Small Diameter Curved Tip Intelligent Reload (45mm Vascular/Thin); CFN: SIGSDL45CTVT;

Covidien, LP

A manufacturing issue could lead to a malformed cover tube press which can lead to internal components' movement during firing - leading to the potential for uncontrolled motion.

September 25, 2025 · DeviceView details →
Class IIOngoing

Cold Form Wrap: Back, REF: DP163CT03-BLK-L,XL, and Shoulder, REF: DP163CT02

DJO, LLC

The IFU (Information for Use) on the wrap instructs the user to heat the hot and cold compression wrap in the microwave for 3 minutes, which may cause the wrap to leak or break at the seams and/or reach temperatures capable of causing a second degree burn.

September 25, 2025 · DeviceView details →
Class IIOngoing

Artegraft¿ Collagen Vascular Graft; REF: AG1015;

LeMaitre Vascular, Inc.

The device was incorrectly packed in the wrong size labeled outer packaging.

September 25, 2025 · DeviceView details →
Class IIOngoing

Brand Name: Aesculap Product Name: SEALING UNIT F/10/12MM TROCARS W.REDUCER Model/Catalog Number: EK083P Software Version: N/A Product Description: SEALING UNIT F/10/12MM TROCARS W.REDUCER Component: N/A

Aesculap Inc

It was determined there is the potential of silicone fragments detaching from the yellow sealing component.

September 24, 2025 · DeviceView details →
Class IIOngoing

Brand Name: AESCULAP Product Name: REDUCING CONVERTER 10/12MM TO 5MM Model/Catalog Number: EK087P Software Version: N/A Product Description: REDUCING CONVERTER 10/12MM TO 5MM Component: N/A

Aesculap Inc

It was determined there is the potential of silicone fragments detaching from the yellow sealing component.

September 24, 2025 · DeviceView details →
Class IIOngoing

Brand Name: Aesculap Product Name: SEALING CAP FOR 10/12MM TROCARS Model/Catalog Number: EK085P Software Version: N/A Product Description: SEALING CAP FOR 10/12MM TROCARS Component: N/A

Aesculap Inc

It was determined there is the potential of silicone fragments detaching from the yellow sealing component.

September 24, 2025 · DeviceView details →
Class IIOngoing

Brand Name: AESCULAP Product Name: SEALING UNIT FOR 10/12MM TROCARS Model/Catalog Number: EK086P Software Version: N/A Product Description: SEALING UNIT FOR 10/12MM TROCARS Component: N/A

Aesculap Inc

It was determined there is the potential of silicone fragments detaching from the yellow sealing component.

September 24, 2025 · DeviceView details →
Class IIOngoing

HARMONIC FOCUS Shears + Adaptive Tissue Technology, 9 cm Length REF: HAR9F, Reprocessed Device for Single Use, STERILEEO, RX ONLY

Stryker Sustainability Solutions

Due to manufacturing issue, reprocessed shears, may become stuck in the "on position" resulting in continuous activation.

September 24, 2025 · DeviceView details →
Class IIOngoing

BD EpiCenter Microbiology Data Management System, labeled as the following: 1. Computer System Epicenter F/G, Catalog Number: 441002. 2. COMPUTER OPTIPLEX EPICENTER SPARE, Catalog Number: 441421. 3. Generic NUC 2, Catalog Number: 445398. 4. Nuc 5i5 Os Image Bow 2.X, Catalog Number: 443971.

Becton Dickinson & Co.

Product service credentials used by some BD technical support teams to access certain BD products were accessed by an unauthorized actor. Until these product service credentials are updated, there is a risk of unauthorized access that may impact the confidentiality, integrity and/or availability of the relevant products and associated data.

September 23, 2025 · DeviceView details →
Class IIOngoing

BD BACTEC Blood Culture System, labeled as the following: 1. BACTEC 9120 System, Catalog Numbers: 445570, 445702. 2. INSTRUMENT BACTEC 9120 UNREPAIRED, Catalog Number: 44557008.

Becton Dickinson & Co.

Product service credentials used by some BD technical support teams to access certain BD products were accessed by an unauthorized actor. Until these product service credentials are updated, there is a risk of unauthorized access that may impact the confidentiality, integrity and/or availability of the relevant products and associated data.

September 23, 2025 · DeviceView details →
Class IIOngoing

Brand Name: Klassic BiPolar Head Model/Catalog Number: 3205.41.022 Klassic BiPolar Head, 41 mm OD, 22 mm Head; 3205.42.022 Klassic BiPolar Head, 42 mm OD, 22 mm Head; 3205.43.022 Klassic BiPolar Head, 43 mm OD, 22 mm Head; 3205.44.028 Klassic BiPolar Head, 44 mm OD, 28 mm Head; 3205.45.028 Klassic BiPolar Head, 45 mm OD, 28 mm Head; 3205.46.028 Klassic BiPolar Head, 46 mm OD, 28 mm Head; 3205.47.028 Klassic BiPolar Head, 47 mm OD, 28 mm Head; 3205.48.028 Klassic BiPolar Head, 48 mm OD, 28 mm Head; 3205.49.028 Klassic BiPolar Head, 49 mm OD, 28 mm Head; 3205.50.028 Klassic BiPolar Head, 50 mm OD, 28 mm Head; 3205.51.028 Klassic BiPolar Head, 51 mm OD, 28 mm Head; 3205.52.028 Klassic BiPolar Head, 52 mm OD, 28 mm Head; 3205.53.028 Klassic BiPolar Head, 53 mm OD, 28 mm Head; 3205.54.028 Klassic BiPolar Head, 54 mm OD, 28 mm Head; 3205.55.028 Klassic BiPolar Head, 55 mm OD, 28 mm Head; 3205.56.028 Klassic BiPolar Head, 56 mm OD, 28 mm Head; 3205.58.028 Klassic BiPolar Head, 58 mm OD, 28 mm Head; 3205.60.028 Klassic BiPolar Head, 60 mm OD, 28 mm Head

Total Joint Orthopedics, Inc.

Potential packaging issue that could compromise the sterile barrier. Defect may result in loss of sterility of the device, presenting potential risk of infection if device is implanted.

September 23, 2025 · DeviceView details →
Class IIOngoing

BD Veritor Connect Software, labeled as the following: 1. Veritor (NUC), Catalog Number: 444881. Transfers in vitro diagnostic results data on the BD Veritor Plus Analyzer to BD Synapsys.

Becton Dickinson & Co.

Product service credentials used by some BD technical support teams to access certain BD products were accessed by an unauthorized actor. Until these product service credentials are updated, there is a risk of unauthorized access that may impact the confidentiality, integrity and/or availability of the relevant products and associated data.

September 23, 2025 · DeviceView details →
Class IIOngoing

BD BACTEC Blood Culture System, labeled as the following: 1. BD BACTEC FX, Instrument Top, Packaged, Catalog Number: 44138509. 2. Instrument Top Remanufactured Bactec Fx, Catalog Number: 441676. 3. BACTEC 9240 System, Catalog Number: 445569. 4. BD BACTEC FX40 Instrument, Catalog Number: 44229609.

Becton Dickinson & Co.

Product service credentials used by some BD technical support teams to access certain BD products were accessed by an unauthorized actor. Until these product service credentials are updated, there is a risk of unauthorized access that may impact the confidentiality, integrity and/or availability of the relevant products and associated data.

September 23, 2025 · DeviceView details →
Class IIOngoing

BIOMET ZipTight, Acute AC Joint Implant, Single Ziploop , Model/Catalog Number: 904834; Fixation System for AC Joint Repair

Biomet, Inc.

There is a potential for a missing slotted button assembly in one lot of ZipTight, Acute AC Joint Implant, Single Ziploop

September 23, 2025 · DeviceView details →