  1. FDA Recalls
  2. ›Device Recalls

FDA Device Recalls

Recalls of medical devices, diagnostic equipment, implants, and surgical instruments.

Classification
AllClass IClass IIClass III
Status
AllOngoingCompletedTerminated
Date
All timePast 30 daysPast 12 months

Showing 521–540 of 1,000 recalls

Class IIOngoing

Brand Name: Quantum Rehab Product Name: Quantum 4Front 2 Model/Catalog Number: Quantum 4Front 2 Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

Pride Mobility Products Corp.

If the "Remind Me Later" option is selected for user reminders, reminder pop-up messages may appear while the wheelchair is in use. If this occurs while driving the wheelchair, the wheelchair may perform an unexpected park brake stop, which may result in fall or injury. If this occurs while not driving the wheelchair, the control system may crash and remain in pre-operational mode.

June 25, 2026 · DeviceView details →
Class IOngoing

Resmed Astral 100/150 Resmed Astral 100/50 is a ventilator system that provides continuous or intermittent ventilatory support for patients weighing more than 11lb (5kg) who require mechanical ventilation.

ResMed Ltd.

Due to a Supercapacitor electrolyte leakage on Printed Circuit Board Assembly (PCBA) may damage the charger chip, causing fail-safe state and interruption of ventilation therapy.

June 25, 2026 · DeviceView details →
Class IIOngoing

Brand Name: Quantum Rehab Product Name: 4Front Model/Catalog Number: 4Front Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

Pride Mobility Products Corp.

If the "Remind Me Later" option is selected for user reminders, reminder pop-up messages may appear while the wheelchair is in use. If this occurs while driving the wheelchair, the wheelchair may perform an unexpected park brake stop, which may result in fall or injury. If this occurs while not driving the wheelchair, the control system may crash and remain in pre-operational mode.

June 25, 2026 · DeviceView details →
Class IIOngoing

Brand Name: Quantum Rehab Product Name: Quantum 1450 Model/Catalog Number: Quantum 1450 Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

Pride Mobility Products Corp.

If the "Remind Me Later" option is selected for user reminders, reminder pop-up messages may appear while the wheelchair is in use. If this occurs while driving the wheelchair, the wheelchair may perform an unexpected park brake stop, which may result in fall or injury. If this occurs while not driving the wheelchair, the control system may crash and remain in pre-operational mode.

June 25, 2026 · DeviceView details →
Class IIOngoing

Brand Name: Quantum Rehab Product Name: Q6 Edge HD Model/Catalog Number: Q6 Edge HD Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

Pride Mobility Products Corp.

If the "Remind Me Later" option is selected for user reminders, reminder pop-up messages may appear while the wheelchair is in use. If this occurs while driving the wheelchair, the wheelchair may perform an unexpected park brake stop, which may result in fall or injury. If this occurs while not driving the wheelchair, the control system may crash and remain in pre-operational mode.

June 25, 2026 · DeviceView details →
Class IIOngoing

Brand Name: Quantum Rehab Product Name: Quantum Rival Model/Catalog Number: Quantum Rival Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

Pride Mobility Products Corp.

If the "Remind Me Later" option is selected for user reminders, reminder pop-up messages may appear while the wheelchair is in use. If this occurs while driving the wheelchair, the wheelchair may perform an unexpected park brake stop, which may result in fall or injury. If this occurs while not driving the wheelchair, the control system may crash and remain in pre-operational mode.

June 25, 2026 · DeviceView details →
Class IIOngoing

Products that contain the Pericare Wipes: Bard¿ Foley Tray With Lubri-Sil¿ All-Silicone Foley Catheter REF: 947314 947316 947318 UDI codes: 00801741024924¿ 10801741024921 00801741024931¿ 10801741024938 00801741024948¿ 10801741024945 Lubri-Sil¿ I.C. Complete Care¿ All-Silicone Foley Catheter Tray REF: 300416A UDI code: 00801741024580 10801741024587 SureStep" Foley Tray System Lubri-Sil¿ IC Complete Care¿ REF: A300416A UDI code: 00801741073762¿ 10801741073769 SureStep" Foley Tray System Lubri-Sil¿ IC Complete Care REF: A303416A UDI code: 00801741073823 10801741073820 SureStep" Foley Tray System Lubri-Sil¿ IC Complete Care¿ REF: A307416A A307418A UDI codes: 00801741104381¿ 10801741104388 00801741100505¿ 10801741100502 SureStep" Foley Tray System Bard¿ Silicone Foley Catheter Tray REF: A897516 UDI code: 00801741073984 10801741073981 SureStep" Foley Tray System Bardex¿ All- Silicone Foley Catheter Tray REF: A902416 UDI code: 00801741074042¿ 10801741074049 SureStep" Foley Tray System Bardex¿ All- Silicone Foley Catheter Tray REF: A902418 UDI code: 00801741074059¿ 10801741074056 SureStep" Foley Tray System Bard¿ Lubri-Sil¿ Foley Catheter REF: A907316 UDI code: 00801741104749¿ 10801741104746 SureStep" Foley Tray System with Bard¿ Lubri-Sil¿ Catheter REF: A942210 UDI code: 00801741100567¿ 10801741100564 SureStep" Foley Tray System with Bard¿ Lubri-Sil¿ Catheter REF: A942212 UDI code: 00801741100536¿ 10801741100533 SureStep" Foley Tray System Bard¿ Lubri-Sil¿ Foley Catheter Tray REF: A942214 UDI code: 00801741074103¿ 10801741074100 SureStep" Foley Tray System Bard¿ Lubri-Sil¿ Foley Catheter Tray REF: A942216 UDI code: 00801741074110 10801741074117 SureStep" Foley Tray System Bard¿ Lubri-Sil¿ Foley Catheter REF: A947316 UDI code: 00801741074141 10801741074148 SureStep" Foley Tray System with Bard¿ Lubri-Sil¿ Catheter REF: A942206 UDI code: 00801741100543 10801741100540 **** Lubri-Sil¿ I.C. Complete Care¿ Temp-Sensing Foley Catheter Tray and Urine Meter REF: 319516AM UDI code: 00801741024696¿ 10801741024693 SureStep" Foley Tray System with Bard¿ Lubri-Sil¿ Temp Sensing Foley Catheter REF: A119214M UDI code: 00801741073670¿ 10801741073677 REF: A119216M UDI code: 00801741073687 10801741073684 SureStep" Foley Tray Lubri-Sil¿ I.C. Complete Care¿ Temp Sensing Catheter REF: A300916A UDI code: 00801741120862¿ 10801741120869 SureStep" Foley Tray System Lubri-Sil¿ IC Complete Care¿ REF: A319516A UDI code: 00801741100338 10801741100335 SureStep" Foley Tray System Lubri-Sil¿ IC Complete Care¿ REF: A319516AM UDI code: 00801741073892 10801741073899 SureStep" Foley Tray Lubri-Sil¿ I.C. Complete Care¿ Temp Sensing Catheter REF: A900916A UDI code: 00801741121029¿ 10801741121026 SureStep" Foley Tray System Lubri-Sil¿ Temperature Sensing Foley Catheter REF: A909216M UDI code: 00801741104763¿ 10801741104760 ***** Bard¿ Urine Meter Foley Catheter Tray With Bard¿ Lubri-Sil¿ Catheter REF 942208 UDI code: 00801741029370 10801741029377 Bard¿ Urine Meter Foley Tray With Lubri-Sil¿ All-Silicone Foley Catheter REF: 942216 UDI code: 00801741024979 10801741024976 Lubri-Sil¿ I.C. Complete Care¿ All-Silicone Foley Catheter Tray and Urine Meter REF: 303416A UDI code: 00801741024726 10801741024723 SureStep" Foley Tray System with Bard¿ Lubri-Sil¿ Temp Sensing Foley Catheter REF: A119218M UDI code: 00801741073694 10801741073691 SureStep" Foley Tray System Lubri-Sil¿ IC Complete Care¿ REF: A300418A UDI code: 00801741073779 10801741073776 SureStep" Foley Tray System Lubri-Sil¿ IC Complete Care¿ REF: A303418A UDI code: 00801741073830 10801741073837 SureStep" Foley Tray System Lubri-Sil¿ IC Complete Care¿ REF: A319514AM UDI code: 00801741073885 10801741073882 SureStep" Foley Tray System with Bard¿ Lubri-Sil¿ Catheter REF: A942208 UDI code: 00801741100550 10801741100557 SureStep" Foley Tray System Bard¿ Lubri-Sil¿ Foley Catheter Tray REF: A942218 UDI code: 00801741074127 10801741074124 SureStep" Foley Tray System Bard¿ Lubri-Sil¿ Foley

C.R. Bard Inc

Due to complaints received indicating presence of contamination on the surface of pericare wipes provided with various Foley and Intermittent Catheter Trays.

June 25, 2026 · DeviceView details →
Class IIOngoing

Pipeline Flex Embolization Device with Shield Technology REF PED2-300-12 UDI-DI code: 00763000448806 he Pipeline Flex Embolization Device with Shield Technology consists of a permanent implant combined with a guidewire based delivery system. The Pipeline Flex Embolization Device with Shield Technology implant is a braided, multi-alloy, mesh cylinder woven from platinum/tungsten and cobalt-chromium-nickel alloy wires and indicated for the endovascular treatment of adults (22 years of age or older) with large or giant wide-necked intracranial aneurysms (IAs) in the internal carotid artery from the petrous to the superior hypophyseal segments.

Micro Therapeutics, Inc.

Due to incorrect label/product dimensions. Product is supposed to be 3.00 mm in diameter, but unit is packaging was a 2.50 mm in diameter.

June 25, 2026 · DeviceView details →
Class IIOngoing

Brand Name: Quantum Rehab Product Name: R-TRAK Model/Catalog Number: R-TRAK Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

Pride Mobility Products Corp.

If the "Remind Me Later" option is selected for user reminders, reminder pop-up messages may appear while the wheelchair is in use. If this occurs while driving the wheelchair, the wheelchair may perform an unexpected park brake stop, which may result in fall or injury. If this occurs while not driving the wheelchair, the control system may crash and remain in pre-operational mode.

June 25, 2026 · DeviceView details →
Class IIOngoing

Brand Name: Quantum Rehab Product Name: Q6 Edge 3 Model/Catalog Number: Q6 Edge 3 Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

Pride Mobility Products Corp.

If the "Remind Me Later" option is selected for user reminders, reminder pop-up messages may appear while the wheelchair is in use. If this occurs while driving the wheelchair, the wheelchair may perform an unexpected park brake stop, which may result in fall or injury. If this occurs while not driving the wheelchair, the control system may crash and remain in pre-operational mode.

June 25, 2026 · DeviceView details →
Class IIOngoing

Products that contain the Pericare Wipes: Bardex Lubricath Foley Catheter Tray REF: 899914 899916 899918 UDI codes: 00801741024801¿ 10801741024808 00801741024818¿ 10801741024815 00801741024825¿ 10801741024822 SureStep" Foley Tray System with Bardex¿ Lubricath Temp Sensing Foley Catheter REF: A119416M UDI code: 00801741073700 10801741073707 SureStep" Foley Tray System Bard¿ Lubricath Foley REF: A800361 UDI code: 00801741073939 10801741073936 SureStep" Foley Tray System Bard¿ Lubricath¿ Foley Catheter Tray REF: A899616 UDI code: 00801741104534¿ 10801741104531 SureStep" Foley Tray System Bardex¿ Lubricath¿ Foley Catheter REF: A899914 UDI code: 00801741074004 10801741074001 SureStep" Foley Tray System Bardex¿ Lubricath¿ Foley Catheter REF: A899916 UDI code: 00801741074011¿ 10801741074018 SureStep" Foley Tray System Bardex¿ Lubricath¿ Temperature Sensing Catheter REF: A900216 UDI code: 00801741120978¿ 10801741120975 SureStep" Foley Tray System Bard¿Lubricath¿ Foley Catheter REF: A902914 A902916 A902918 UDI code: 00801741074066¿10801741074063 00801741074073 10801741074070 00801741074080¿10801741074087 Bard¿ Urine Meter Foley Catheter Tray With Bardex¿ Lubricath¿ Foley Catheter REF: 304916 UDI code: 00801741019736 01801741019739 Bard¿ Urine Meter Foley Catheter Tray With Bardex¿ Lubricath¿ Foley Catheter REF: 902916 UDI codes: 00801741024863 10801741024860 (416A) SureStep Foley Tray System Bardex IC Complete Care (714A/716A/718A)SureStep Foley Tray System Bardex IC Complete REF: A304914 A304916 A304918 UDI codes: 00801741104350¿ 10801741104357 00801741104367¿ 10801741104364 00801741100499¿ 10801741100496 SureStep" Foley Tray System Bard¿ Lubricath Foley REF: A800365 UDI codes: 00801741073960 10801741073967 SureStep" Foley Tray System Bardex¿ Lubricath¿ Foley Catheter REF: A899918 UDI codes: 00801741074028 10801741074025 SureStep" Foley Tray System Bard¿Lubricath¿ Foley Catheter REF: A902618 UDI codes: 00801741104640 10801741104647 SureStep" Foley Tray System Bard¿Lubricath¿ Foley Catheter REF: A902616 UDI codes: 00801741104633¿ 10801741104630 SureStep Intermittent Catheter Tray REF: INTL16C UDI codes: 00801741183195¿ 10801741183192 For urological use only, Intended for use in the drainage and/or collection and/or measurement of urine.

C.R. Bard Inc

Due to complaints received indicating presence of contamination on the surface of pericare wipes provided with various Foley and Intermittent Catheter Trays.

June 25, 2026 · DeviceView details →
Class IIOngoing

Products that contain the Pericare Wipes: (Canada Only) SureStep" Foley Tray System Bardex¿ IC Complete Care¿ REF: A300314AC UDI-DI code: 00801741143243 SureStep" Foley Tray System Bardex¿ IC Complete Care¿ REF: A300316AC UDI-DI code: 00801741143250 SureStep" Foley Tray System Lubri-Sil¿ IC Complete Care¿ REF: A319516AMC UDI-DI code: 00801741143472 SureStep" Foley Tray System Bard¿ Lubricath Foley REF: A800366C UDI-DI code: 00801741143571 SureStep" Foley Tray System Bard¿ Silicone Foley Catheter Tray REF: A897514C UDI-DI code: 00801741074011¿ SureStep" Foley Tray System Bard¿ Silicone Foley Catheter Tray REF: A897516C UDI-DI code: 00801741143595 SureStep" Foley Tray System Bard¿ Silicone Foley Catheter Tray REF: A902114C UDI-DI code: 00801741144325 ***** SureStep" Foley Tray System Lubri-Sil¿ IC Complete Care REF: A300416AC UDI code: 00801741143281 10801741143288 SureStep" Foley Tray System Bardex¿ IC Complete Care REF: A303314AC UDI code: 00801741143304 10801741143301 SureStep" Foley Tray System Lubri-Sil¿ IC Complete Care REF: A319514AMC UDI code: 00801741143465 10801741143462 SureStep" Foley Tray System Bard¿ Lubricath¿ Foley Catheter Tray REF: A800061C UDI code: 00801741144172 10801741144179 SureStep" Foley Tray System Bard¿ Lubricath¿ Foley Catheter Tray REF: A800065C UDI code: 00801741144202 10801741144209 SureStep" Foley Tray System Bard¿ Lubricath¿ Foley Catheter Tray REF: A800360C UDI code: 00801741143519 10801741143516 SureStep" Foley Tray System Bard¿ Lubricath¿ Foley Catheter Tray REF:A800361C UDI code: 00801741143526 10801741143523 SureStep" Foley Tray System Bard¿ Lubricath¿ Foley Catheter Tray REF: A800362C UDI code: 00801741143540 10801741143547 SureStep" Foley Tray System Bard¿ Lubricath Foley REF: A800365C UDI code: 00801741143564 10801741143561 For urological use only, Intended for use in the drainage and/or collection and/or measurement of urine.

C.R. Bard Inc

Due to complaints received indicating presence of contamination on the surface of pericare wipes provided with various Foley and Intermittent Catheter Trays.

June 25, 2026 · DeviceView details →
Class IIOngoing

Brand Name: Quantum rehab Product Name: Q6 Edge 2.0 Model/Catalog Number: Q6 Edge 2.0 Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

Pride Mobility Products Corp.

If the "Remind Me Later" option is selected for user reminders, reminder pop-up messages may appear while the wheelchair is in use. If this occurs while driving the wheelchair, the wheelchair may perform an unexpected park brake stop, which may result in fall or injury. If this occurs while not driving the wheelchair, the control system may crash and remain in pre-operational mode.

June 25, 2026 · DeviceView details →
Class IIOngoing

Products that contain the Pericare Wipes: SureStep Intermittent Catheter Tray REF: INTP16 INTS14 INTS14C INTS16 INTS16C PEDINTS06 PEDINTS08 PEDINTS10 UDI code: 00801741183300¿ 10801741183307 00801741183218¿ 10801741183215 00801741183232 10801741183239 00801741183225¿ 10801741183222 00801741183249 10801741183246 00801741183263¿ 10801741183260 00801741183270¿ 10801741183277 00801741183287¿ 10801741183284 Preamendment REF: INTL14 INTL15 INTL16 INTP14 UDI code: 00801741183164¿ 10801741183161 00801741183171¿ 10801741183178 00801741183188 10801741183185 00801741183294 10801741183291 For urological use only, Intended for use in the drainage and/or collection and/or measurement of urine.

C.R. Bard Inc

Due to complaints received indicating presence of contamination on the surface of pericare wipes provided with various Foley and Intermittent Catheter Trays.

June 25, 2026 · DeviceView details →
Class IIOngoing

Products that contain the Pericare Wipes: *Bardex¿ I.C. Complete Care¿ Foley Catheter Tray REF: 300316A UDI codes: 00801741024344¿ 10801741024341 *Bardex¿ I.C. Complete Care¿ Foley Catheter Tray and Urine Meter REF: 303314A 303316A 303318A UDI code: 00801741024252¿ 10801741024259 00801741024269 10801741024266 00801741024276¿ 10801741024273 *SureStep" Foley Tray System Bardex¿ IC Complete Care¿ REF: A300314A UDI codes: 00801741073724¿ 10801741073721 REF: A300314AC (Canada Only) UDI-DI code: 00801741143243 *SureStep" Foley Tray System Bardex¿ IC Complete Care¿ REF: A300316A UDI code: 00801741073731 10801741073738 *SureStep" Foley Tray System Bardex¿ IC Complete Care¿ REF: A300318A UDI code: 00801741073748¿ 10801741073745 *SureStep" Foley Tray System Bardex¿ IC Complete Care¿ REF: A303314A A303316A A303318A UDI code: 00801741073786¿ 10801741073783 00801741073793¿ 10801741073790 00801741073809¿ 10801741073806 *SureStep" Foley Tray System Lubri-Sil¿ IC Complete Care¿ REF: A303414A UDI code: 00801741073816¿ 10801741073813 *(416A)SureStep" Foley Tray System Bardex¿ IC Complete Care¿ (714A/716A/718A)SureStep" Foley Tray System Bardex¿ IC Complete Care¿ (914)SureStep" Foley Tray System REF: A304716A A304714A A304716A A304718A UDI code: 00801741104206¿ 10801741104203 00801741104268 10801741104265 00801741104299¿ 10801741104296 00801741100376¿ 10801741100373 *SureStep" Foley Tray System Bardex¿ IC Complete Care¿ REF: A319416A UDI code: 00801741100307¿ 10801741100304 *SureStep" Foley Tray System Bardex¿ I.C. Complete Care Foley Catheter REF: A319416AM UDI code: 00801741073861¿ 10801741073868 *SureStep" Foley Tray System Bardex¿ IC Complete Care¿ REF: A319418A UDI code: 00801741100314¿ 10801741100311 SureStep" Foley Tray System Bardex¿ IC Complete Care¿ REF: A903316A UDI code: 00801741096600¿ 10801741096607 ***** SureStep" Foley Tray System Lubri-Sil¿ IC Complete Care REF: A300414A UDI code: 00801741073755 10801741073752 SureStep" Foley Tray System Bardex¿ I.C. Complete Care Foley Catheter REF: A319414AM UDI code: 00801741073854 10801741073851 SureStep" Foley Tray System Bardex¿ I.C. Complete Care Foley Catheter REF: A319418AM UDI code: 00801741073878 10801741073875 SureStep" Foley Tray System Bardex¿ IC Complete Care REF: A903318A UDI code: 00801741104657 10801741104654 For urological use only, Intended for use in the drainage and/or collection and/or measurement of urine.

C.R. Bard Inc

Due to complaints received indicating presence of contamination on the surface of pericare wipes provided with various Foley and Intermittent Catheter Trays.

June 25, 2026 · DeviceView details →
Class IIOngoing

Brand Name: Quantum Rehab Product Name: Q6 Edge 4 Model/Catalog Number: Q6 Edge 4 Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

Pride Mobility Products Corp.

If the "Remind Me Later" option is selected for user reminders, reminder pop-up messages may appear while the wheelchair is in use. If this occurs while driving the wheelchair, the wheelchair may perform an unexpected park brake stop, which may result in fall or injury. If this occurs while not driving the wheelchair, the control system may crash and remain in pre-operational mode.

June 25, 2026 · DeviceView details →
Class IIOngoing

Brand Name: Quantum Rehab Product Name: Q6 Edge 2.0 (ilevel) Model/Catalog Number: Q6 Edge 2.0 (ilevel) Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

Pride Mobility Products Corp.

If the "Remind Me Later" option is selected for user reminders, reminder pop-up messages may appear while the wheelchair is in use. If this occurs while driving the wheelchair, the wheelchair may perform an unexpected park brake stop, which may result in fall or injury. If this occurs while not driving the wheelchair, the control system may crash and remain in pre-operational mode.

June 25, 2026 · DeviceView details →
Class IIOngoing

Brand Name: Quantum Rehab Product Name: Quantum 4Front 2HD Model/Catalog Number: Quantum 4Front 2HD Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

Pride Mobility Products Corp.

If the "Remind Me Later" option is selected for user reminders, reminder pop-up messages may appear while the wheelchair is in use. If this occurs while driving the wheelchair, the wheelchair may perform an unexpected park brake stop, which may result in fall or injury. If this occurs while not driving the wheelchair, the control system may crash and remain in pre-operational mode.

June 25, 2026 · DeviceView details →
Class IIOngoing

V-Loc 180 Absorbable Wound Closure Device BOX BEDSIDE STAPLING IS KING BOX06614V4 BOX BY PASS FINAL BOX07405V1 BOX BYPASS CARDON BOX01056V2 BOX BYPASS DR LAGAE BOX01482V2 BOX BYPASS KIT DEZEMBER 2025 BOX09222V1 BOX BYPASS KIT NEU BOX 003 BOX08767V1 BOX GASTRIC BYPASS JAWBYPASS2 BOX GASTRIC BYPASS SIGNIA BOX02191V11 BOX GASTRICBYPASS KIT V4 BOX06863V4 BOX GB BOX MET LHOOK PST04884V3 BOX GB ZONDER ENDOHERNIA EGIA PST04884V6 BOX GBP SIGNIA BOX08506V2 BOX KIT COLON IHS KIT00625V1 BOX KIT HERNIA HIATO IHS KIT01026V1 BOX LAP HERNIE INGUNIAL RIGHT BOX00051V4 BOX NEW GBP KIT PST03130V2 BOX ZESTAW DO BARIATRII GB UCKGB5 BOX ZESTAW DO RYGB WEJRYGB3 VLOCL0013 V-LOC* 180 4-0 CLR 30CM P12 VLOCL0013 VLOCL0014 V-LOC* 180 3-0 CLR 30CM P12 VLOCL0014 VLOCL0023 V-LOC* 180 4-0 CLR 45CM P12 VLOCL0023 VLOCL0024 V-LOC* 180 3-0 CLR 45CM P12 VLOCL0024 VLOCL0306 V-LOC 180 DEVICE 0 15CM GS-21 VLOCL0306 VLOCL0316 V-LOC* 180 0 GRN 30CM GS21X12 VLOCL0316 VLOCL0345 V-LOC* 180 2-0 GRN 23CM GS21 VLOCL0345 VLOCL0436 V-LOC* 180 0 GRN 60CM GS25X12 VLOCL0436 VLOCL0604 V-LOC* 180 3-0 GRN 15CM V20 VLOCL0604 VLOCL0615 V-LOC* 180 2-0 GRN 30CM V20 VLOCL0615 VLOCL0625 V-LOC* 180 2-0 GRN 45CM V20 VLOCL0625 VLOCL0644 V-LOC* 180 3-0 GRN 23CM V20 VLOCL0644 VLOCL0804 V-LOC 180 3-0 GRN 15CM CV23 VLOCL0804 VLOCL2105 V-LOC* 180 2-0 GRN 15CM GS22 VLOCL2105 VLOCL2145 V-LOC* 180 2-0 GRN 23CM GS22 VLOCL2145 VLOCL2246 VLOC180 0 GRN 9 GS-22 VLOCL2246

Covidien, LP

Product may contain a perforation or tear in the sterile barrier packaging. This issue may result in biocontamination of the sterile sutures, which may lead to infection, loss of vision if in ophthalmic utilization, or prolonged surgery.

June 24, 2026 · DeviceView details →
Class IIOngoing

EOPA Elongated One-Piece Arterial Cannula DIL TIP 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 77722

Medtronic Perfusion Systems

Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction.

June 24, 2026 · DeviceView details →