  1. FDA Recalls
  2. ›Device Recalls

FDA Device Recalls

Recalls of medical devices, diagnostic equipment, implants, and surgical instruments.

Classification
AllClass IClass IIClass III
Status
AllOngoingCompletedTerminated
Date
All timePast 30 daysPast 12 months

Showing 341–360 of 786 recalls

Class IIITerminated

Sage In-Vitro Fertilization- CSC (Choline Substituted Cryopreservation) Freezing Medium . Product Number: ART -8017 SAGE In Vitro Fertilization, Inc. A CooperSurgical Company 95 Corporate Drive Trumbull, CT 06611 USA

CooperSurgical, Inc.

Products contain international package insert and not the correct USA package insert

August 25, 2016 · DeviceView details →
Class IIITerminated

Sage In-Vitro Fertilization- CSC (Choline Substituted Cryopreservation) Thawing Medium Product Number: ART-8018 Intended for use in freezing embryos. This product is intended for thawing of embryos frozen with ART-8017, CSC Freezing Medium. This kit is designed to be used in conjunction with the SAGE CSC Freezing Medium Kit (ART-8017).

CooperSurgical, Inc.

Products contain international package insert and not the correct USA package insert

August 25, 2016 · Device
View details →
Class IIITerminated

Arthrex Suture Washer

Arthrex, Inc.

The device was assembled incorrectly. Suture and washer were not assembled; components were placed loose in the package.

August 12, 2016 · DeviceView details →
Class IIITerminated

Sabouraud Dextrose Agar w /Lecithin and Tween 20 Acumedia PN 91081 Product Usage: Used for the isolation of fungi from surfaces sanitized with quaternary ammonium compounds

Acumedia Manufacturers, Inc.

Storage temperature listed on the label was incorrect. Label stated 2-30¿C. Actual storage temperature is 2-8¿C.

August 8, 2016 · DeviceView details →
Class IIITerminated

LDX Optical Check Cassettes (OCC) Model Number: 10-228 and 14-535 Cassette in box with foam insert. The cassette is used to check the optics system of the LDX analyzer. Product Usage: The Optics Check Cassette is used to check the optics system of the Alere Cholestech LDX¿ Analyzer. It is run once a day before patient samples are tested and after the analyzer has been moved or serviced.

Alere San Diego, Inc.

Incorrect expiration date on the magnetic strip that does not match the labeled expiration date.

August 2, 2016 · DeviceView details →
Class IIITerminated

VITROS Immunodiagnostic Products TSH Reagent Pack, REF/Catalog Number/Product Code 191 2997, Unique Device Identifier No. 10758750000227, IVD --- Ortho-Clinical Diagnostics Pencoed Bridgend CF35 5PZ UK For the in vitro quantitative measurement of thyroid stimulating hormone (TSH) in human serum and plasma (EDTA or heparin) using the VITROS ECi/ECiQ Immunodiagnostic Systems, the VITROS 3600 Immunodiagnostic System and the VITROS 5600 Integrated System to aid in the differential diagnosis of thyroid disease.

ORTHO-CLINICAL DIAGNOSTICS

A field correction was issued by the firm for VITROS TSH reagent lot 5040 due to a higher than expected frequency of customer calibration curves falling outside of the calibration quality parameters and therefore unusable to process samples. Customers using VITROS TSH Lot 5040 will potentially experience an unexpected increase in the unsuccessful calibrations potentially causing a delay in testing and reporting results for VITROS TSH.

July 28, 2016 · DeviceView details →
Class IIITerminated

Creatinine/Endpoint [Modified Heinegard-Tiderstrom] for IN VITRO DIAGNOSTIC USE in the quantitative determination of analytes. These are CONSUMABLES - a customer buys another when kit is consumed.

Sterling Diagnostics, Inc.

Sterling Diagnostics, Inc. initiated a recall on 7/20/2016 for multiple diagnostic kits due to a recision of the previously extended expiration dates for the kits.

July 20, 2016 · DeviceView details →
Class IIITerminated

Sterling Diagnostics, Inc.Colorimetric SGOT for IN VITRO DIAGNOSTIC USE in the quantitative determination of analytes. These are CONSUMABLES - a customer buys another when kit is consumed.

Sterling Diagnostics, Inc.

Sterling Diagnostics, Inc. initiated a recall on 7/20/2016 for multiple diagnostic kits due to a recision of the previously extended expiration dates for the kits.

July 20, 2016 · DeviceView details →
Class IIITerminated

Enzymatic Cholesterol (Trinder/COD-CEH) for IN VITRO DIAGNOSTIC USE in the quantitative determination of analytes. These are CONSUMABLES - a customer buys another when kit is consumed.

Sterling Diagnostics, Inc.

Sterling Diagnostics, Inc. initiated a recall on 7/20/2016 for multiple diagnostic kits due to a recision of the previously extended expiration dates for the kits.

July 20, 2016 · DeviceView details →
Class IIITerminated

Sterling Diagnostics, Inc., Enzymatic Uric Acid (Uricase Trinder) for IN VITRO DIAGNOSTIC USE in the quantitative determination of analytes. These are CONSUMABLES - a customer buys another when kit is consumed.

Sterling Diagnostics, Inc.

Sterling Diagnostics, Inc. initiated a recall on 7/20/2016 for multiple diagnostic kits due to a recision of the previously extended expiration dates for the kits.

July 20, 2016 · DeviceView details →
Class IIITerminated

Sterling Diagnostics, Inc., Enzymatic Glucose for IN VITRO DIAGNOSTIC USE in the quantitative determination of analytes. These are CONSUMABLES - a customer buys another when kit is consumed.

Sterling Diagnostics, Inc.

Sterling Diagnostics, Inc. initiated a recall on 7/20/2016 for multiple diagnostic kits due to a recision of the previously extended expiration dates for the kits.

July 20, 2016 · DeviceView details →
Class IIITerminated

Sterling Diagnostics, Inc., HDL Cholesterol (PEF Method) for IN VITRO DIAGNOSTIC USE in the quantitative determination of analytes. These are CONSUMABLES - a customer buys another when kit is consumed.

Sterling Diagnostics, Inc.

Sterling Diagnostics, Inc. initiated a recall on 7/20/2016 for multiple diagnostic kits due to a recision of the previously extended expiration dates for the kits.

July 20, 2016 · DeviceView details →
Class IIITerminated

Sterling Diagnostics, Inc., SGPT Colorimetric for IN VITRO DIAGNOSTIC USE in the quantitative determination of analytes. These are CONSUMABLES - a customer buys another when kit is consumed.

Sterling Diagnostics, Inc.

Sterling Diagnostics, Inc. initiated a recall on 7/20/2016 for multiple diagnostic kits due to a recision of the previously extended expiration dates for the kits.

July 20, 2016 · DeviceView details →
Class IIITerminated

Urea Nitrogen/Color BUN (Enzymatic Berthelot) for IN VITRO DIAGNOSTIC USE in the quantitative determination of analytes. These are CONSUMABLES - a customer buys another when kit is consumed.

Sterling Diagnostics, Inc.

Sterling Diagnostics, Inc. initiated a recall on 7/20/2016 for multiple diagnostic kits due to a recision of the previously extended expiration dates for the kits.

July 20, 2016 · DeviceView details →
Class IIITerminated

Sterling Diagnostics, Inc. Serum Iron/IBC (Colorimetric) for IN VITRO DIAGNOSTIC USE in the quantitative determination of analytes. These are CONSUMABLES - a customer buys another when kit is consumed.

Sterling Diagnostics, Inc.

Sterling Diagnostics, Inc. initiated a recall on 7/20/2016 for multiple diagnostic kits due to a recision of the previously extended expiration dates for the kits.

July 20, 2016 · DeviceView details →
Class IIITerminated

BD Tritest CD3 FITC/CD4 PE/CD45 PerCP (IVD); Catalog number 340383. Label states: Contains CD3 FITC/CD4 PE/CD45 per CP with Gelatin and 0.1% sodium azide. Hematology: BD Tritest CD3 fluorescein isothiocyanate (FITC)/CD4 phycoerythrin (PE)/CD45 peridinin chlorophyll protein (PerCP) is a three-color direct immunofluorescence reagent for use with a suitably equipped flow cytometer to identify and determine the percentages and absolute counts of mature human T lymphocytes (CD3+) and helper/inducer (CD3+CD4+) Tlymphocyte subsets in erythrocyte-lysed whole blood.

Becton, Dickinson and Company, BD Biosciences

Internal review found that some vials of CD3/CD4/CD45 state that the product contains gelatin. The product does not contain gelatin and should state in buffer.

July 18, 2016 · DeviceView details →
Class IIITerminated

Viva-ProE Systems, Model # 6003-670, UDI: 03661540600357 - Product Usage: The ELITech Clinical Systems Selectra ProM is an automated clinical chemistry system intended for use in clinical laboratories. It is intended to be used for a variety of assay methods that have been applied to spectrophotometric and electrochemical techniques. The system has two core modules: one consisting of a spectrophoto-metric system for measurement of analytes using spectrophotometric techniques, such as end point, rate and turbidometric assays. The second module is an electro-meter used for measurement of electrolytes.

ELITech Group B.V.

Software malfunction; The action being taken due to the device becoming inoperable due to software lockup.

July 12, 2016 · DeviceView details →
Class IIITerminated

Trinity Biotech Captia Measles IgM, REF/Product Code 2326060,Test Kit for 96 Determinations, IVD

Clark Laboratories, Inc. (dba,Trinity Biotech USA)

The product lot failed to meet QC acceptance criteria during stability testing. The Calibrator OD was dropping causing the positive control to be invalid (running high out of range).

July 11, 2016 · DeviceView details →
Class IIITerminated

The TM Ardis Interbody System implant is a convex, straight TLIF or PLIF device for interbody fusion of the anterior column of the spine. TM Ardis is designed for fusing the adjacent bony surfaces and may be used to replace a disc at one or two contiguous levels in L2-S1. The superior and inferior surfaces of the device are textured to provide increased stability and convex to conform to the vertebral endplates. The device also has two slots on the posterior end to mate with the insertion instrument. The TM Ardis device is wholly comprised of Trabecular Metal Porous Tantalum. Surgical instrumentation for use with the proposed system will be fabricated from surgical grade stainless steel and other applicable materials.

Zimmer Trabecular Metal Technology, Inc.

This field action is being initiated following the firm's discovery of a procedural error in the approval of literature resulting in the undo release of certain content. Information was disseminated to distributors and sales representatives during the 2016 National Sales Meeting held February 17-21, 2016.

July 7, 2016 · DeviceView details →
Class IIITerminated

AmediCheck Instant Test Cup, Part No. C-C0501A-3A Product Usage: The AmediCheck Instant Test Cup is an in vitro diagnostic test for the rapid detection of the following drugs in human urine. Drug Analyte Cut off Device Code Marijuana THC 50 ng/mL THC Cocaine Benzoylecgonine 300 ng/mL COC Amphetamine Amphetamine 1000 ng/mL AMP Methamphetamine Methamphetamine 1000 ng/mL MET Opiates Morphine 2000 ng/mL OPI Opiates300 Morphine 300 ng/ml OPI300 Phencyclidine Phencyclidine 25 ng/mL PCP Barbiturates Secobarbital 300 ng/mL BAR Benzodiazepines Oxazepam 300 ng/mL BZD Methadone Methadone 300 ng/mL MTD Oxycodone Oxycodone 100 ng/mL OXY MDMA MDMA 500 ng/mL MDMA Tricyclic Antidepressants Nortriptyline 1000 ng/mL TCA

Branan Medical Corporation

Branan Medical is recalling the AmediCheck Instant Test Cup, a 5 panel drug cup, because it may erroneously contain 12 panel cups due to a packaging error.

July 5, 2016 · DeviceView details →
← PreviousPage 18 of 40Next →