  1. FDA Recalls
  2. ›Device Recalls

FDA Device Recalls

Recalls of medical devices, diagnostic equipment, implants, and surgical instruments.

Classification
AllClass IClass IIClass III
Status
AllOngoingCompletedTerminated
Date
All timePast 30 daysPast 12 months

Showing 561–580 of 1,000 recalls

Class IITerminated

BF-1T180 EVIS EXERA II Bronchovideoscope, Model No. BF-1T180

Olympus Corporation of the Americas

The firm is issuing validated, new reprocessing instructions according to the FDA 2015 guidance, "Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling."

August 16, 2021 · DeviceView details →
Class IITerminated

BF-3C40 OES Bronchofiberscope, Model No. BF-3C40

Olympus Corporation of the Americas

The firm is issuing validated, new reprocessing instructions according to the FDA 2015 guidance, "Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling."

August 16, 2021 · DeviceView details →
Class IITerminated

BF-XT160 EVIS EXERA Bronchovideoscope, Model No. BF-XT160

Olympus Corporation of the Americas

The firm is issuing validated, new reprocessing instructions according to the FDA 2015 guidance, "Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling."

August 16, 2021 · DeviceView details →
Class IITerminated

AtomLab 500Plus Dose CalibratorSoftware 2.0.00 through Revision 2.0.08, inclusive Model: 086-332

Biodex Medical Systems, Inc.

When deleting a previously entered custom isotope, the software deletes the isotope, but not the associated dial setting. Possible other stored custom isotopes may then have incorrect dial settings and may lead to an incorrect dose measurement and/or misadministration

August 16, 2021 · DeviceView details →
Class IITerminated

BF-1T60 OES Bronchofiberscope, Model No. BF-1T60

Olympus Corporation of the Americas

The firm is issuing validated, new reprocessing instructions according to the FDA 2015 guidance, "Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling."

August 16, 2021 · DeviceView details →
Class IITerminated

BF-N20 OES Bronchofiberscope, Model No. BF-N20

Olympus Corporation of the Americas

The firm is issuing validated, new reprocessing instructions according to the FDA 2015 guidance, "Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling."

August 16, 2021 · DeviceView details →
Class IITerminated

BF-P60 OES Bronchofiberscope, Model No. BF-P60

Olympus Corporation of the Americas

The firm is issuing validated, new reprocessing instructions according to the FDA 2015 guidance, "Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling."

August 16, 2021 · DeviceView details →
Class IITerminated

BF-Q180-AC EVIS EXERA II Bronchovideoscope, Model No. BF-Q180-AC

Olympus Corporation of the Americas

The firm is issuing validated, new reprocessing instructions according to the FDA 2015 guidance, "Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling."

August 16, 2021 · DeviceView details →
Class IITerminated

BF-XP160F EVIS EXERA Bronchovideoscope, Model No. BF-XP160F

Olympus Corporation of the Americas

The firm is issuing validated, new reprocessing instructions according to the FDA 2015 guidance, "Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling."

August 16, 2021 · DeviceView details →
Class IITerminated

BF-P180 EVIS EXERA II Bronchovideoscope, Model No. BF-P180

Olympus Corporation of the Americas

The firm is issuing validated, new reprocessing instructions according to the FDA 2015 guidance, "Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling."

August 16, 2021 · DeviceView details →
Class IITerminated

The Allura Xper series is intended for use on human patients to perform: "Vascular, cardiovascular and neurovascular imaging applications, including diagnostic, interventional and minimally invasive procedures. This includes, e.g., peripheral, cerebral, thoracic and abdominal angiography, as well as PTAs, stent placements, embolisations and thrombolysis. "Cardiac imaging applications including diagnostics, interventional and minimally invasive procedures (such as PTCA, stent placing, atherectomies), pacemaker implanatations, and electrophysiology (EP). "Non-vascular interventions such as drainages, biopsies and vertebroplasties procedures."

Philips North America Llc

Early life failure of the ADUs only occurs when the hospital mains provide 480V to the system. This current voltage may lead to saturation and overheating of the coils that protect the IGBTs (insulated-gate bipolar transistor) of the ADU. The overheating may generate a peculiar burning smell that may be noticed. In some instances, this burning smell may be noticed before the ADU fails. When the ADU fails the X-ray performance of the system is reduced to Emergency Fluoroscopy. Exposure will not be possible and image quality will be reduced.

August 13, 2021 · DeviceView details →
Class IITerminated

The Azurion series (within the limits of the used Operation Room table) are intended for use to perform: "Image guidance in diagnostic, interventional and minimally invasive surgery procedures for the following clinical application areas: vascular, non-vascular, cardiovascular and neuro procedures. "Cardiac imaging applications including diagnostics, interventional and minimally invasive surgery procedures. Additionally: "The Azurion series can be used in a hybrid Operation Room. "The Azurion series contain a number of features to support a flexible and patient centric procedural workflow.

Philips North America Llc

Early life failure of the ADUs only occurs when the hospital mains provide 480V to the system. This current voltage may lead to saturation and overheating of the coils that protect the IGBTs (insulated-gate bipolar transistor) of the ADU. The overheating may generate a peculiar burning smell that may be noticed. In some instances, this burning smell may be noticed before the ADU fails. When the ADU fails the X-ray performance of the system is reduced to Emergency Fluoroscopy. Exposure will not be possible and image quality will be reduced.

August 13, 2021 · DeviceView details →
Class IITerminated

VACUETTE TUBE 6 ml K2E K2EDTA 13x100 pink cap-pink ring, non-ridged

Greiner Bio-One North America, Inc.

Blood collection tubes may experience a clotting issue.

August 13, 2021 · DeviceView details →
Class IITerminated

Lyra Direct SARS-CoV-2 Assay Emergency Use Authorization- Ref: M124. The Lyra Direct SARS-CoV-2 Assay is a real-time RT-PCR assay intended for the qualitative detection of nucleic acid from SARS-CoV-2 in nasal (NS), nasopharyngeal (NP), or oropharyngeal (OP) direct swab specimens from individuals suspected of COVID-19 by their healthcare provider

Quidel Corporation

Revised Instructions for Use: Potential for specimens from patients with high SARS-CoV-2 viral loads to be falsely interpreted as negative if target amplification occurs prior to a cycle-threshold (Ct) value of 5 when using the Thermo Fisher QuantStudio 7 Pro, the Applied Biosystems 7500 Fast Dx, the Applied Biosystems 7500, the Bio-Rad CFX96 Touch", the Roche LightCycler LC 480 II/ cobas z 480, or the Qiagen Rotor-Gene¿ MDx.

August 13, 2021 · DeviceView details →
Class IITerminated

The Allura Xper series is intended for use on human patients to perform: "Vascular, cardiovascular and neurovascular imaging applications, including diagnostic, interventional and minimally invasive procedures. This includes, e.g., peripheral, cerebral, thoracic and abdominal angiography, as well as PTAs, stent placements, embolisations and thrombolysis." "Cardiac imaging applications including diagnostics, interventional and minimally invasive procedures (such as PTCA, stent placing, atherectomies), pacemaker implanatations, and electrophysiology (EP). Non-vascular interventions such as drainages, biopsies and vertebroplasties procedures."

Philips North America Llc

Early life failure of the ADUs only occurs when the hospital mains provide 480V to the system. This current voltage may lead to saturation and overheating of the coils that protect the IGBTs (insulated-gate bipolar transistor) of the ADU. The overheating may generate a peculiar burning smell that may be noticed. In some instances, this burning smell may be noticed before the ADU fails. When the ADU fails the X-ray performance of the system is reduced to Emergency Fluoroscopy. Exposure will not be possible and image quality will be reduced.

August 13, 2021 · DeviceView details →
Class IITerminated

Centricity Universal Viewer 7.0, Model 5829628-0XX. Radiological image processing system

GE Healthcare, LLC

A software anomaly exists in the Centricity Universal Viewer study management feature in which study changes are not propagated to either the Centricity Enterprise Archive (EA) or another Vendor Neutral Archive (VNA).

August 12, 2021 · DeviceView details →
Class IITerminated

McKesson Lap Sponge, X-Ray Detectable 12"x 12", 5/pack, Sterile McKesson Part # 16-2112121

Cypress Medical Products LLC

Manufacturer issued a recall due to an EO indicator color. The indicator should change from red to blue signifying sterilization. However, on one case of product, the indicators did not change

August 11, 2021 · DeviceView details →
Class IITerminated

REGARD Vitrectomy Tray

ROi CPS LLC

Povidone-Iodine swabstick manufactured by PDI, Inc. recalled due to Out of Specifications was used as a component in some of the ROI CPS, LLC products.

August 10, 2021 · DeviceView details →
Class IITerminated

REGARD Ear Tray

ROi CPS LLC

Povidone-Iodine swabstick manufactured by PDI, Inc. recalled due to Out of Specifications was used as a component in some of the ROI CPS, LLC products.

August 10, 2021 · DeviceView details →
Class IITerminated

TRUMATCH CT CUT GUIDE KIT L- TruMatch Patient Specific Instruments are intended to be used as patient-specific surgical instrumentation to assist in the positioning of a joint replacement component intra-operatively and in guiding the marking of bone before cutting Part Number: 420915

DePuy Orthopaedics, Inc.

Software: A coding error associated with the Fast3D Segmentation software. During the scanning process the three images required of the hip, knee and ankle may not be aligned, causing the anatomic landmark locations to potentially result in limb malalignment.

August 10, 2021 · DeviceView details →
← PreviousPage 29 of 50Next →