  1. FDA Recalls
  2. ›Device Recalls

FDA Device Recalls

Recalls of medical devices, diagnostic equipment, implants, and surgical instruments.

Classification
AllClass IClass IIClass III
Status
AllOngoingCompletedTerminated
Date
All timePast 30 daysPast 12 months

Showing 361–380 of 1,000 recalls

Class IITerminated

BARD SURESTEP INTERMITTENT CATHETER TRAY, 14Fr, REF INTS16C

C.R. Bard Inc

There is a potential to leak from the catheter where it connects to the drain bag

January 27, 2022 · DeviceView details →
Class IITerminated

LineSider Spinal System 5.5/6.0mm, Non-mod Standard 7.1mm - Dual Lead, Cannulated. Thoracolumbosacral pedicle screw system; Spinal interlaminal fixation orthosis. Product sold as non-sterile and shipped in protective sterilization trays. Screws can also be shipped individually, as tray replenishments. Labeled as the following sizes: a. 5.5mm x 35mm; b. 5.5mm x 40mm; c. 5.5mm x 45mm; d. 5.5mm x 50mm; e. 5.5mm x 55mm; f. 6.5mm x 35mm; g. 6.5mm x 40mm; h. 6.5mm x 45mm; i. 6.5mm x 50mm; j. 6.5mm x 55mm; k. 6.5mm x 60mm; l. 7.5mm x 35mm; m. 7.5mm x 40mm; n. 7.5mm x 45mm; o. 7.5mm x 50mm; p. 7.5mm x 55mm; q. 7.5mm x 60mm; r. 8.5mm x 35mm; s. 8.5mm x 40mm; t. 8.5mm x 45mm; u. 8.5mm x 50mm; v.8.5mm x 55mm; w. 8.5mm x 60mm; Used in spinal fixation surgery.

Integrity Implants Inc.

Potential for weld separation of the Upper Tulip Head component from the Lower Tulip Head component, which would result in the separation of the Tulip Head from the Screw Shank.

January 27, 2022 · DeviceView details →
Class IITerminated

LineSider Spinal System 5.5/6.0mm, Non-mod MIS 7.1mm - Dual Lead, Cannulated. Thoracolumbosacral pedicle screw system; Spinal interlaminal fixation orthosis. Product sold as non-sterile and shipped in protective sterilization trays. Screws can also be shipped individually, as tray replenishments. Labeled as the following sizes: a. 5.5mm x 35mm; b. 5.5mm x 40mm; c. 5.5mm x 45mm; d. 5.5mm x 50mm; e. 6.5mm x 35mm; f. 6.5mm x 40mm; g. 6.5mm x 45mm; h. 6.5mm x 50mm; i. 6.5mm x 55mm; j. 7.5mm x 35mm; k. 7.5mm x 40mm; l. 7.5mm x 45mm; m. 7.5mm x 50mm; n. 7.5mm x 55mm; o. 8.5mm x 35mm; p. 8.5mm x 40mm; q. 8.5mm x 45mm; r. 8.5mm x 50mm; s.8.5mm x 55mm; t. 9.5mm x 35mm; u. 9.5mm x 40mm; v. 9.5mm x 45mm; w. 9.5mm x 50mm; x. 9.5mm x 55mm; Used in spinal fixation surgery.

Integrity Implants Inc.

Potential for weld separation of the Upper Tulip Head component from the Lower Tulip Head component, which would result in the separation of the Tulip Head from the Screw Shank.

January 27, 2022 · DeviceView details →
Class IITerminated

LineSider Spinal System 5.5/6.0mm, Non-mod Standard 7.1mm - Dual Lead, Non-cannulated. Thoracolumbosacral pedicle screw system; Spinal interlaminal fixation orthosis. Product sold as non-sterile and shipped in protective sterilization trays. Screws can also be shipped individually, as tray replenishments. Labeled as the following sizes: a. 5.5mm x 35mm; b. 5.5mm x 40mm; c. 5.5mm x 45mm; d. 5.5mm x 50mm; e. 5.5mm x 55mm; f. 6.5mm x 35mm; g. 6.5mm x 40mm; h. 6.5mm x 45mm; i. 6.5mm x 50mm; j. 6.5mm x 55mm; k. 6.5mm x 60mm; l. 7.5mm x 35mm; m. 7.5mm x 40mm; n. 7.5mm x 50mm; o. 7.5mm x 55mm; p. 7.5mm x 60mm; q. 8.5mm x 35mm; r. 8.5mm x 40mm; s. 8.5mm x 45mm; t. 8.5mm x 50mm; u.8.5mm x 55mm; v. 8.5mm x 60mm; Used in spinal fixation surgery.

Integrity Implants Inc.

Potential for weld separation of the Upper Tulip Head component from the Lower Tulip Head component, which would result in the separation of the Tulip Head from the Screw Shank.

January 27, 2022 · DeviceView details →
Class IITerminated

CoolSeal Generator, REF: CSL-200-50

Bolder Surgical, LLC

A potential manufacturing/assembly defect could result in the generator not meeting IEC 60601 standards for medical electrical equipment, and it can potentially, under specific conditions, lead to the delivery of unintended energy to the patient.

January 25, 2022 · DeviceView details →
Class IITerminated

meridian bioscience immunocard STAT! Rotavirus test, REF 750030, 30 tests/kit box. The ImmunoCard STAT! Rotavirus Immunoassay is a rapid in vitro qualitative procedure for the detection of rotavirus antigen in human stool. The test can be used to aid in the diagnosis of rotavirus associated gastroenteritis.

MEDLINE INDUSTRIES, LP - Northfield

The product was incorrectly shipped at room temperature rather than refrigerated.

January 25, 2022 · DeviceView details →
Class IITerminated

Codman Cranial Access Kits- indicated when a craniotomy is required for placement of an intracranial pressure (ICP) monitoring device and/or cerebrospinal fluid drainage procedures. Part Number: 826616

Integra LifeSciences Corp.

Incorrect extended expiration dates identified on the outer box label only, if product is used past the correct expiration date there is a potential for pain, infection, or adverse tissue reaction to occur

January 21, 2022 · DeviceView details →
Class IITerminated

REF: 5921-018-135, Stryker Color Cuff, 18" (Red), Quick Connect Single Port, Single Bladder

Stryker Sustainability Solutions

Mislabeling; dual-bladder tourniquet cuffs are labeled as single-bladder inflatable cuffs.

January 21, 2022 · DeviceView details →
Class IITerminated

Codman Cranial Access Kits- indicated when a craniotomy is required for placement of an intracranial pressure (ICP) monitoring device and/or cerebrospinal fluid drainage procedures. Product umber: 826614

Integra LifeSciences Corp.

Incorrect extended expiration dates identified on the outer box label only, if product is used past the correct expiration date there is a potential for pain, infection, or adverse tissue reaction to occur

January 21, 2022 · DeviceView details →
Class IITerminated

Del(5q) Deletion FISH Probe Kit: In-Vitro Diagnostic to detect deletions in chromosome location from patients with AML or MDS Catalog Number: USA-LPH024

Cytocell Ltd.

individual components have been labelled with incorrect colours. The red and green colours are opposite to those specified in the product labelling. The EGR1 probe is labelled in green rather than red and the control probe labelled in red rather than green. The expected positive signal pattern in the case of 1x deleted 5q will be 1G2R instead of 1R2G, an incorrect result

January 18, 2022 · DeviceView details →
Class IITerminated

Merete PediatrOS RigidTack, REF CP20120, Size 20 mm, Sterile, Rx Only

Merete Medical GmbH

Incorrect marketing label (25 mm) was applied to product size 20 mm.

January 18, 2022 · DeviceView details →
Class IITerminated

LINQ II Insertable Cardiac Monitor

Medtronic Inc., Cardiac Rhythm and Heart Failure (CRHF)

Devices may lose functionality due to susceptibility to moisture ingress.

January 18, 2022 · DeviceView details →
Class IITerminated

BUTLER Clear Dip, 12 bottles/case

Sunstar Americas, Inc.

Product lacks premarket clearance.

January 14, 2022 · DeviceView details →
Class IITerminated

(1)Traverse Rail Carrier E-System, wide 31017XX component to Liko overhead lift, (2)Traverse Rail Carrier 31025XX component to Liko overhead lift. Intended for to make safe lifting of a patient possible. Affected Devices: 3101704 TRAV RAIL CARR E-SYST STD 3102514 TR CARRIER SLIM/RAISED, LR 3101705 TRAV RAIL CARR ESYST WIDE 3102517 TR CARR. NORMAL/LOWER. LR 3102506 TR CARRIER WIDE/RAISED ML 3102519 TR CARR. LOW.LR 30MM/PAIR 3102511 TR CARRIER NORMAL, LR 3102531 TRAVERSE RL CARRIER STD/RAISED 3102512 TR CARRIER WIDE, LR 3102532 TRAVERSE RL CARRIER WD/RAISED 3102513 TR CARRIER SLIM, LR 3102562 TR CARRIER, PARALLEL/WIDE

Hill-Rom, Inc.

Traverse rail carriage delivered with non-conforming screws are too short to ensure appropriate installation. There is potential that the screws are unable to secure the traverse rail appropriately and could loosen over time causing the rail system to fall, potentially causing injury to caregivers and/or patients

January 14, 2022 · DeviceView details →
Class IITerminated

HEMASHIELD GOLD KNITTED MICROVEL DOUBLE VELOUR VASCULAR GRAFT- D: 7 mm; L: 60 cm Indicated for use in the replacement or repair of arteries affected with aneurysmal or occlusive disease. Product Code/REF Number: M002020952070

Maquet Cardiovascular, LLC

Outer labelling (HEMASHIELD GOLD Knitted Microvel Double Velour Bifurcated Vascular Graft, D: 16 x 8 mm; L: 40 cm) does not correspond to the (inner) sterile packaging labelling (HEMASHIELD GOLD Knitted Microvel Double Velour Straight Vascular Graft, D: 7 mm L: 60 cm). Mislabeled product could cause a disruption of the vascular anastomosis in the long term, creating a pseudo-aneurysm

January 14, 2022 · DeviceView details →
Class IITerminated

Regard, TOTAL HIP - SPRINGFIELD, Item No. 8800297010, Case Quantity: 2, Sterile

ROi CPS LLC

Products are mislabeled with the incorrect product identification on individual kit labeling.

January 13, 2022 · DeviceView details →
Class IITerminated

Nextra CH Cannulated Hammertoe Mini Instrument Kit-indicated for small bone reconstruction limited to inter-digital repair and fusion of the lesser toes SKU: CH-MINI-KT

Nextremity Solutions

During insertion of the middle phalanx implant into bone, the driver may deform the implant locking mechanism and result in inadequate mating force between the middle and proximal phalanx implants, resulting in surgical delay, in-situ removal of the implant, use of alternative surgical approach, disassembly of the implants post-operatively, and revision

January 13, 2022 · DeviceView details →
Class IITerminated

Nextra Cannulated Hammertoe Standard Instrument Kit-indicated for small bone reconstruction limited to inter-digital repair and fusion of the lesser toe SKU: CH-STD-KT

Nextremity Solutions

During insertion of the middle phalanx implant into bone, the driver may deform the implant locking mechanism and result in inadequate mating force between the middle and proximal phalanx implants, resulting in surgical delay, in-situ removal of the implant, use of alternative surgical approach, disassembly of the implants post-operatively, and revision

January 13, 2022 · DeviceView details →
Class IITerminated

CARA (Computer Assisted Retinal Analysis), Product ID: +B543CARA0/$$+7V4.7.2/16D202111179

Diagnos Inc

Retinal analysis system software has some features, based on artificial intelligence, that potentially lack appropriate market approval, so it is recommended to use a specific prior software version.

January 11, 2022 · DeviceView details →
Class IITerminated

Thermo Scientific Sensititre Gram Negative Susceptibility Testing Plate, IVD format

Remel Inc

There are lower than expected MICs for some gram negative species.

January 10, 2022 · DeviceView details →